m+Medelevator.RU
← Поиск публикаций
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 1994

Myocardial perfusion scintigraphy in heart transplant recipients with and without allograft atherosclerosis: a comparison of thallium-201 and technetium 99m sestamibi.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rodney R A, Johnson L L, Blood D K, Barr M L

Аннотация

Our objectives were to assess the comparative value of thallium-201 and technetium 99m sestamibi for the detection of cardiac allograft atherosclerosis and the left ventricular ejection fraction response to exercise in heart transplant recipients with and without allograft atherosclerosis. Allograft atherosclerosis is the critical factor limiting long-term survival in heart transplant recipients. Annual coronary angiography is invasive and expensive. A noninvasive test to detect allograft atherosclerosis would be clinically useful. Treadmill exercise testing followed by myocardial perfusion single-photon computed tomographic imaging was performed in 25 heart transplant recipients. All patients underwent coronary angiography. Group 1 (13 patients) had angiographic coronary artery disease; group 2 (12 patients) did not. Eighteen patients underwent two exercise tests to equivalent work loads with thallium-201 and technetium 99m sestamibi; seven patients underwent only thallium-201 imaging. First-pass left ventricular ejection fraction was measured during injection of technetium 99m sestamibi. In group 1, 10 of 13 patients had abnormal thallium-201 scans. There was no significant difference in the number of patients who had abnormal thallium-201 (7/10) and technetium 99m sestamibi scans (6/10). Fifty-two percent (12/23) of discordantly scored segments were reversible on thallium-201 and fixed on technetium 99m sestamibi imaging compared with the opposite (0%; 0/23) (p < 0.01). All patients in group 2 had normal perfusion scans. There were no false-positive scans.(ABSTRACT TRUNCATED AT 250 WORDS)

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты