m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2024

A Systematic Review and Meta-Analysis of the Efficacy and Safety of Combined Mechanical Circulatory Support in Acute Myocardial Infarction Related Cardiogenic Shock.

СтатьяСистематический обзорМетаанализНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Soh Bing Wei Thaddeus, Gracias Carlos Sebastian, Dean Afshan, Kumar Jathinder, Asgedom Solomon, Matiullah Sajjad, Owens Patrick

Аннотация

BACKGROUND: Acute myocardial infarction-related cardiogenic shock (AMICS) is a severe complication associated with exceedingly high mortality rates. While mechanical circulatory support (MCS) has emerged as a potential intervention, the evidence base for independent MCS use remains weak. In contrast, systematic reviews of observational studies have revealed significant mortality reduction when a combination of MCS was used: VA-ECMO in conjunction with a left ventricular (LV) unloading device (Impella or IABP). The ongoing dilemma concerning the selection between two LV unloading devices (VA-ECMO + Impella vs. VA-ECMO + IABP) warrants further investigation and clarification.

AIM: This is the first systematic review and meta-analysis assessing the short-term efficacy and safety of VA-ECMO + Impella versus VA-ECMO + IABP in treatment of AMICS.

METHODS: A systematic search was performed on the EMBASE, MEDLINE, and Cochrane databases. Studies reporting the short-term (30-day/inpatient) mortality and complications of adult patients with AMICS treated with VA-ECMO + Impella and VA-ECMO + IABP were included. Subgroup analysis was performed including studies with ACS predominant CS (CS etiology 100% by AMI).

RESULTS: Four observational studies with 14,247 patients were included. There was no significant difference in mortality between VA-ECMO + Impella and VA-ECMO + IABP (56.5% vs. 66.5%; OR, 0.90; 95% CI, 0.79-1.02; p = 0.09). However, VA-ECMO + Impella was associated with significantly lower mortality in patients with ACS predominant CS (53.2% vs. 67.7%; OR, 0.72; 95% CI, 0.62-0.85; p < 0.0001). VA-ECMO + Impella was concomitantly associated with a significantly higher risk of complications.

CONCLUSIONS: When comparing LV unloading devices in patients with AMICS requiring a combination of MCS, VA-ECMO + Impella was superior in mortality reduction only in the cohort where 100% of CS was caused by AMI.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты