Moderate correlation between breath-holding and CO(2) inhalation/hyperventilation methods for transcranial doppler evaluation of cerebral vasoreactivity.

Haussen Diogo C, Katsnelson Michael, Rodriguez Abiezer, Campo Nelly, Campo-Bustillo Iszet, Romano Jose G, Koch Sebastian

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Both CO(2) inhalation followed by hyperventilation and breath-holding have been utilized to measure cerebral vasomotor reactivity (VMR) but their correlation has been poorly studied and understood.

METHODS

A retrospective study was conducted in 143 subjects (62.6 ± 15.8 years old, 64% men) with transcranial Doppler ultrasonography measurement of mean flow velocity (MFV) at baseline, after 30 seconds of breath-holding, and after CO(2) inhalation followed by hyperventilation, in the left and right middle cerebral artery. Breath-holding index (BHI) was calculated as the percentage of MFV increase from baseline per second of apnea. CO(2) inhalation/hyperventilation index (CO(2) /HV) was calculated as the percentage of MFV difference between CO(2) inhalation and hyperventilation.

RESULTS

There were 75 carotid arteries with >70% stenosis or occlusion, and 18 middle cerebral arteries with >50% stenosis or occlusion. The mean BHI was 0.93 ± 0.7 and 0.89 ± 0.6, whereas the mean CO(2) /HV was 61 ± 26% and 60 ± 26%, respectively, on the right and left sides. The correlation between BHI and CO(2) /HV was moderate on the right (r = 0.33; p < 0.01) and left sides (r = 0.38; p < 0.01). Multivariate linear regression analysis indicated that age (p = 0.01) and history of stroke (p = 0.007) were associated independently with an impaired VMR on the right as measured by CO(2) /HV. No predictors for impaired VMR by CO(2) /HV on the left and by BHI on either side were found.

CONCLUSIONS

CO(2) /HV and BHI are only moderately correlated. Further studies are necessary to determine which method more accurately predicts clinical morbidity. © 2012 Wiley Periodicals, Inc. J Clin Ultrasound 2012; Published online in Wiley Online Library.

Для цитирования: Haussen Diogo C, Katsnelson Michael, Rodriguez Abiezer, Campo Nelly, Campo-Bustillo Iszet, Romano Jose G, Koch Sebastian. Moderate correlation between breath-holding and CO(2) inhalation/hyperventilation methods for transcranial doppler evaluation of cerebral vasoreactivity.. Journal of clinical ultrasound : JCU. 2012. DOI: 10.1002/jcu.21944.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.