Journal of shoulder and elbow surgery · 2016
Press-fit bipolar radial head arthroplasty, midterm results.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kodde Izaäk F, Heijink Andras, Kaas Laurens, Mulder Paul G H, van Dijk C Niek, Eygendaal Denise
Аннотация
BACKGROUND: Theoretical advantages of bipolar compared with monopolar radial head arthroplasty include better accommodation of radiocapitellar malalignment, reduction of capitellar abrasion, and reduction of stress at the bone-implant interfaces. Our purpose was to report the midterm results of press-fit bipolar radial head arthroplasty.
METHODS: Thirty patients were treated by press-fit bipolar radial head arthroplasty for acute fracture of the radial head, failed earlier treatment, or post-traumatic sequelae. Three patients were lost to follow-up. Results are presented for the remaining 27 patients.
RESULTS: At mean follow-up of 48 months (range, 28-73), there had been 3 (11%) revisions. Two involved conversion to prosthetic radiocapitellar hemiarthroplasty for symptomatic capitellar abrasion; a third involved exchange of the articular component (ie, head) for instability. In all, the stems appeared well fixed. A prosthesis in a subluxed position accounted for the 1 (4%) additional radiologic failure. The average flexion-extension arc was 136° (range, 120°-145°), and the average pronation-supination arc was 138° (range, 70°-180°). According to the Mayo Elbow Performance Score, the combined excellent and good results accounted for 70%.
CONCLUSIONS: The overall midterm outcome of this series of 30 press-fit bipolar radial head arthroplasties can be considered favorable. Although the revision rate was 11%, the stems were well fixed in all. There was 1 (4%) additional radiologic failure. We suggest considering a press-fit bipolar radial head prosthesis for acute comminuted radial head fractures with limited bone loss of the proximal radius.
METHODS: Thirty patients were treated by press-fit bipolar radial head arthroplasty for acute fracture of the radial head, failed earlier treatment, or post-traumatic sequelae. Three patients were lost to follow-up. Results are presented for the remaining 27 patients.
RESULTS: At mean follow-up of 48 months (range, 28-73), there had been 3 (11%) revisions. Two involved conversion to prosthetic radiocapitellar hemiarthroplasty for symptomatic capitellar abrasion; a third involved exchange of the articular component (ie, head) for instability. In all, the stems appeared well fixed. A prosthesis in a subluxed position accounted for the 1 (4%) additional radiologic failure. The average flexion-extension arc was 136° (range, 120°-145°), and the average pronation-supination arc was 138° (range, 70°-180°). According to the Mayo Elbow Performance Score, the combined excellent and good results accounted for 70%.
CONCLUSIONS: The overall midterm outcome of this series of 30 press-fit bipolar radial head arthroplasties can be considered favorable. Although the revision rate was 11%, the stems were well fixed in all. There was 1 (4%) additional radiologic failure. We suggest considering a press-fit bipolar radial head prosthesis for acute comminuted radial head fractures with limited bone loss of the proximal radius.