Improved diagnostic performance of insertable cardiac monitors by an artificial intelligence-based algorithm.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Crespin Eliot, Rosier Arnaud, Ibnouhsein Issam, Gozlan Alexandre, Lazarus Arnaud, Laurent Gabriel, Menet Aymeric, Bonnet Jean-Luc, Varma Niraj

Аннотация

AIMS: The increasing use of insertable cardiac monitors (ICM) produces a high rate of false positive (FP) diagnoses. Their verification results in a high workload for caregivers. We evaluated the performance of an artificial intelligence (AI)-based ILR-ECG Analyzer™ (ILR-ECG-A). This machine-learning algorithm reclassifies ICM-transmitted events to minimize the rate of FP diagnoses, while preserving device sensitivity.

METHODS AND RESULTS: We selected 546 recipients of ICM followed by the Implicity™ monitoring platform. To avoid clusterization, a single episode per ICM abnormal diagnosis (e.g. asystole, bradycardia, atrial tachycardia (AT)/atrial fibrillation (AF), ventricular tachycardia, artefact) was selected per patient, and analyzed by the ILR-ECG-A, applying the same diagnoses as the ICM. All episodes were reviewed by an adjudication committee (AC) and the results were compared. Among 879 episodes classified as abnormal by the ICM, 80 (9.1%) were adjudicated as 'Artefacts', 283 (32.2%) as FP, and 516 (58.7%) as 'abnormal' by the AC. The algorithm reclassified 215 of the 283 FP as normal (76.0%), and confirmed 509 of the 516 episodes as abnormal (98.6%). Seven undiagnosed false negatives were adjudicated as AT or non-specific abnormality. The overall diagnostic specificity was 76.0% and the sensitivity was 98.6%.

CONCLUSION: The new AI-based ILR-ECG-A lowered the rate of FP ICM diagnoses significantly while retaining a > 98% sensitivity. This will likely alleviate considerably the clinical burden represented by the review of ICM events.