Andre Jalal B, Oztek Murat Alp, Anzai Yoshimi, Wilson Gregory J, Mossa-Basha Mahmud, Hippe Daniel S, Hoff Michael N, Cross Donna J, Minoshima Satoshi

Аннотация

BACKGROUND AND PURPOSE: To assess the feasibility of 3-dimensional stereotactic surface projection (3D-SSP) as applied to arterial spin labeling (ASL) in a clinical pilot study.

METHODS: A retrospective sample of 10 consecutive patients who underwent ASL as part of a clinically indicated MR examination was collected during this pilot study. Five additional subjects with normal cerebral perfusion served as a control group. Following voxel-wise M0-correction, cerebral blood flow (CBF) quantification, and stereotactic anatomic standardization, voxel-wise CBF from an individual's ASL dataset was extracted to a set of predefined surface pixels (3D-SSP). A normal database was created from averaging the extracted CBF datasets of the control group. Patients' datasets were compared individually with the normal database by calculating a Z-score on a pixel-by-pixel basis and were displayed in 3D-SSP views for visual inspection. Independent, two-expert reader assessment, using a 3-point scale, compared standard quantitative CBF images to the 3D-SSP maps.

RESULTS: Patterns and severities of regionally reduced CBF were identified, by both independent readers, in the 3D-SSP maps. Reader assessment demonstrated preference for 3D-SSP over traditionally displayed standard quantitative CBF images in three of four evaluated imaging metrics (p = .026, .031, and .013, respectively); 3D-SSP maps were never found to be inferior to the standard quantitative CBF images.

CONCLUSIONS: Three-dimensional SSP maps are feasible in a clinical population and enable quantitative data extraction and localization of perfusion abnormalities by means of stereotactic coordinates in a condensed display. The proposed method is a promising approach for interpreting cerebrovascular pathophysiology.