DOI 10.1161/circulationaha.113.006191
Transplantation-free survival and interventions at 3 years in the single ventricle reconstruction trial.
Аннотация
BACKGROUND
In the Single Ventricle Reconstruction (SVR) trial, 1-year transplantation-free survival was better for the Norwood procedure with right ventricle-to-pulmonary artery shunt (RVPAS) compared with a modified Blalock-Taussig shunt (MBTS). At 3 years, we compared transplantation-free survival, echocardiographic right ventricular ejection fraction, and unplanned interventions in the treatment groups.
METHODS AND
RESULTS
Vital status and medical history were ascertained from annual medical records, death indexes, and phone interviews. The cohort included 549 patients randomized and treated in the SVR trial. Transplantation-free survival for the RVPAS versus MBTS groups did not differ at 3 years (67% versus 61%; P=0.15) or with all available follow-up of 4.8±1.1 years (log-rank P=0.14). Pre-Fontan right ventricular ejection fraction was lower in the RVPAS group than in the MBTS group (41.7±5.1% versus 44.7±6.0%; P=0.007), and right ventricular ejection fraction deteriorated in RVPAS (P=0.004) but not MBTS (P=0.40) subjects (pre-Fontan minus 14-month mean, -3.25±8.24% versus 0.99±8.80%; P=0.009). The RVPAS versus MBTS treatment effect had nonproportional hazards (P=0.004); the hazard ratio favored the RVPAS before 5 months (hazard ratio=0.63; 95% confidence interval, 0.45-0.88) but the MBTS beyond 1 year (hazard ratio=2.22; 95% confidence interval, 1.07-4.62). By 3 years, RVPAS subjects had a higher incidence of catheter interventions (P<0.001) with an increasing HR over time (P=0.005): <5 months, 1.14 (95% confidence interval, 0.81-1.60); from 5 months to 1 year, 1.94 (95% confidence interval, 1.02-3.69); and >1 year, 2.48 (95% confidence interval, 1.28-4.80).
CONCLUSIONS
By 3 years, the Norwood procedure with RVPAS compared with MBTS was no longer associated with superior transplantation-free survival. Moreover, RVPAS subjects had slightly worse right ventricular ejection fraction and underwent more catheter interventions with increasing hazard ratio over time.
CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00115934.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.