MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mvr.2022.104452

Медицинская библиотека · Microvascular research · 2022

The micro-pathological characteristics in cerebral arteriovenous malformations(cAVMs).

Zhang Haibin, Peng Hao, Yan Debin, Wang Ke, Yuan Kexin, Chen Yu, Li Zhipeng, Li Ruinan, Li Runting, Lu Junlin, Chen Xiaolin, Ye Xun, Wang Hao, Zhao Yuanli, Hao Qiang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Rupture and hemorrhage is the most serious complication of cerebral arteriovenous malformation(cAVMs), and have a significant impact on quality of life.

OBJECTIVES

We investigated the hematoxylin and eosin staining and ultrastructural features of cAVMs and characterized the abnormal vascular structure of cAVMs.

METHODS

Light and electron microscopy were performed on a series of pathological specimens obtained from 12 patients with cAVMs who underwent surgical resection for the first time without radiosurgery or embolization therapy.

RESULTS

In tunica intima, we found that the vascular endothelial cells of cAVMs were damaged, and the lysis of the cell body occurred in multiple regions. In tunica media, the arrangement of the elastic layer was disordered, and the thickness was uneven. Part of the structure of the elastic lamina was missing. The part of tunica adventitia was fractured and discontinuous. In addition, we also observed the phenomenon that different blood vessels share the same vascular wall. Macrophage phagocytosis and lymphocyte infiltration in the adventitial region of ruptured cAVMs. Abnormal lipid deposition in vascular endothelial cells and smooth muscle cells.

CONCLUSIONS

The structural incompleteness of cAVMs may be an important cause of hemorrhage.

Для цитирования: Zhang Haibin, Peng Hao, Yan Debin, Wang Ke, Yuan Kexin, Chen Yu, Li Zhipeng, Li Ruinan, Li Runting, Lu Junlin, Chen Xiaolin, Ye Xun, Wang Hao, Zhao Yuanli, Hao Qiang. The micro-pathological characteristics in cerebral arteriovenous malformations(cAVMs).. Microvascular research. 2022. DOI: 10.1016/j.mvr.2022.104452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.