MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/00045632211027612

Медицинская библиотека · Annals of clinical biochemistry · 2021

Uninterpretable cerebrospinal fluid absorbance scans caused by antibiotic therapy.

Miller Jan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The revised national guidelines for analysis of cerebrospinal fluid for bilirubin in suspected subarachnoid haemorrhage (UK) provide an objective means of assessing cerebrospinal fluid samples to determine the risk of subarachnoid haemorrhage. The guidelines are intended for general use, but samples rendered uninterpretable due to the presence of the antibiotic doxycycline have been described. Here, further cases of antibiotic-based interference, and their implications, are presented.

METHODS

An archival search of cerebrospinal fluid spectra performed at Hallands County Hospital Halmstad was performed for the years 2011 and 2016-2019 in an attempt to locate instances of interference. Each case of suspected interference was further investigated with in vitro reproduction experiments as a means of confirmation and assessment of potential clinical impact.

RESULTS

A total of 10 cases of cerebrospinal fluid curve interference were discovered: six due to doxycycline, three due to metronidazole and one due to tetracycline. Interference caused by the tetracycline class was revealed through in vitro experimentation to cause an apparent decrease in the sample's net bilirubin absorbance; the presence of xanthochromia on visual inspection was, however, conserved.

CONCLUSIONS

The problem of cerebrospinal fluid absorbance curve interference might be more common than previously suspected. Due to the potential net bilirubin absorbance-lowering effect of tetracyclines, the author recommends visual examination of cerebrospinal fluid samples in every case.

Для цитирования: Miller Jan. Uninterpretable cerebrospinal fluid absorbance scans caused by antibiotic therapy.. Annals of clinical biochemistry. 2021. DOI: 10.1177/00045632211027612.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.