Theranostics · 2020
Serum piRNA-54265 is a New Biomarker for early detection and clinical surveillance of Human Colorectal Cancer.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mai Dongmei, Zheng Yanfen, Guo Huan, Ding Peirong, Bai Ruihong, Li Mei, Ye Ying, Zhang Jialiang, Huang Xudong, Liu Dingxin, Sui Qiaoqi, Pan Ling, Su Jiachun, Deng Junge, Wu Guandi, Li Rui, Deng Shuang, Bai Yansen, Ligu Yanan, Tan Wen, Wu Chen, Wu Tangchun, Zheng Jian, Lin Dongxin
Аннотация
Background: Our previous study has demonstrated an oncogenic role of PIWI-interacting RNA-54265 (piR-54265) in colorectal cancer (CRC). Here, we investigate whether it can be a blood biomarker for population screening and clinical applications. Methods: Serum piR-54265 levels were determined by a digital PCR method in 209 cancer-free healthy controls, 725 patients with CRC, 1303 patients with other types of digestive cancer and 192 patients with benign colorectal tumors. A prospective case-control analysis was conducted to assess the predictive value of serum piR-54265 for future CRC diagnosis. Receiver operating characteristic (ROC) curve was constructed to quantify the diagnostic performance of serum piR-54265 levels by assessing its sensitivity, specificity and respective areas under curve (AUC). The odds ratios (ORs) were computed using multivariate logistic regression models. Results: Serum piR-54265 levels were significantly elevated only in patients with CRC compared with controls and patients with other cancer types. The AUC for recognizing CRC was 0.896 (95% CI, 0.874-0.914), with a sensitivity and specificity being 85.7% and 65.1% at 1500 copies/µL as a cut-off value. The serum piR-54265 levels in patients declined substantially after surgery but increased significantly again when tumor relapses. The prediagnostic serum piR-54265 levels were significantly associated with future CRC diagnosis, with the ORs of 7.23, 2.80, 2.45, and 1.24 for those whose CRC was diagnosed within 1, 2, 3 and >3 years. Serum piR-54265 test is more sensitive than other blood CRC markers. Conclusion: Serum piR-54265 may serve as a valuable biomarker for CRC screening, early detection and clinical surveillance.
Предметные рубрики MeSH
Area Under CurveBiomarkers, TumorCase-Control StudiesCell Line, TumorColorectal NeoplasmsEarly Detection of CancerFemaleGene Expression Regulation, NeoplasticHCT116 CellsHT29 CellsHumansMaleOdds RatioPolymerase Chain ReactionProspective StudiesRNA, Small InterferingSensitivity and SpecificityUp-Regulation