Aortic Root Geometric and Dynamic Changes After Device Closure of Interatrial Shunts.

Abdelghani Mohammad, Nassif Martina, de Bruin-Bon Rianne H A C M, Al-Amin Ali M, El-Baz Mohammed S, El-Shedoudy Sahar A O, Mulder Barbara J M, de Winter Robbert J, Bouma Berto J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The spatial relationship between atrial septal occluders and the aorta and the subsequent impact on the geometry and mechanics of the aortic root have been underinvestigated. The aim of this study was to evaluate occluder-aorta interaction after device closure of an atrial septal defect (ASD) or a patent foramen ovale (PFO) using three-dimensional transesophageal echocardiography and two-dimensional speckle-tracking echocardiography.

METHODS

In 65 adult patients (mean age, 47 ± 14 years; 71% women) who underwent ASD (n = 35) or PFO (n = 30) closure with the Amplatzer Septal Occluder or Amplatzer PFO Occluder, occluder-aorta contact was evaluated on three-dimensional transesophageal echocardiography and defined as continuous, intermittent, or absent. Sinus of Valsalva diameter, height, eccentricity, and strain were measured before and immediately after occluder implantation.

RESULTS

The occluder/total septal length and occluder/body surface area ratios were significantly larger after PFO than after ASD closure. The occluder was in contact with the aorta in 93.8% of cases (ASD, 91.4%; PFO, 96.7%). After ASD closure, occluder-aorta contact was very common, in patients with an aortic rim < 5 mm (100%) and those with an aortic rim ≥ 5 mm (79%). However, continuous occluder-aorta contact was more frequent in those with an aortic rim < 5 mm (95% vs 50%). Factors influencing aortic root strain after occluder implantation included the pattern of occluder-aorta relationship and the occluder/body surface area ratio.

CONCLUSIONS

Most interatrial septal occluders are in contact with the aortic root, even in patients with ASDs with a sufficient aortic rim and in patients with PFOs. However, continuous occluder-aorta contact is more likely in patients with ASDs with a deficient aortic rim. The pattern of occluder-aorta relationship and the occluder/body surface area ratio affect aortic root strain.

Для цитирования: Abdelghani Mohammad, Nassif Martina, de Bruin-Bon Rianne H A C M, Al-Amin Ali M, El-Baz Mohammed S, El-Shedoudy Sahar A O, Mulder Barbara J M, de Winter Robbert J, Bouma Berto J. Aortic Root Geometric and Dynamic Changes After Device Closure of Interatrial Shunts.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2019. DOI: 10.1016/j.echo.2019.03.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.