MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resp.2022.103941

Медицинская библиотека · Respiratory physiology & neurobiology · 2022

Exertional Dyspnoea responses reported in the Dyspnoea Challenge and measures of disease severity in COPD.

Aitken Craig R, Walsh James R, Stewart Glenn M, Sabapathy Surendran, Adams Lewis, Morris Norman R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The Dyspnoea Challenge has been developed to facilitate the field-based measure of exertional dyspnoea(ED). To further validate the test, we aimed to; investigate the relationship between end-exercise ED, generated by a fixed-intensity Dyspnoea Challenge(DCFIX), and measures of disease severity (Forced expiratory volume in 1 s(FEV1), six-minute walk distance(6MWD), breathing reserve(V̇E/MVV), modified medical research council dyspnoea scale (mMRC), Body-mass index, airflow Obstruction, Dyspnoea, and Exercise (BODE index) and compare the physiological response of the DCFIX to a six-minute walk test(6MWT).

METHODS

Thirty-two individuals (15 female) with COPD (GOLD II-IV) (age: 69.7 ± 9.4 yrs; FEV1: 49.1 ± 18.2 %) performed 2×6MWT and 2xDCFIX at a treadmill speed of 3 km h-1 and gradient of 4 %. The intensity of ED was measured using the modified Borg dyspnoea scale at baseline and end-exercise with heart rate (HR) and oxygen saturation (SpO2) monitored continuously. During 1×6MWT and 1xDCFIX pulmonary gas exchange, cardiac output (Q̇) and dynamic hyperinflation were measured.

RESULTS

End-exercise ED measured during the DCFIX was not correlated to FEV1, but moderately correlated to; 6MWD(rs = -0.54, P < .01), V̇E/MVV (rs = 0.46, P = .02), mMRC(rs = 0.45, P = .01), and the BODE index(rs = 0.53, P < .01). When comparing the DCFIX and 6MWT, participants walked to comparable levels of oxygen consumption(P = .38), ventilation(P = .37), Q̇(P = .20), V̇E/MVV(P = .83), maximum HR percentages(P = .67) and dynamically hyperinflated to a similar degree(P = .37).

CONCLUSIONS

The Dyspnoea Challenge is correlated to different parameters of disease severity and produces a similar physiological and ED response to that of the 6MWT with the added benefit of being appropriate for longitudinal assessment of ED.

Для цитирования: Aitken Craig R, Walsh James R, Stewart Glenn M, Sabapathy Surendran, Adams Lewis, Morris Norman R. Exertional Dyspnoea responses reported in the Dyspnoea Challenge and measures of disease severity in COPD.. Respiratory physiology & neurobiology. 2022. DOI: 10.1016/j.resp.2022.103941.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.