MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/112972980200300307

Медицинская библиотека · The journal of vascular access · 2002

Vascular rupture during angioplasty of hemodialysis raft-related stenoses.

Pappas J N, Vesely T M

СтатьяПеревод в очереди

Аннотация

PURPOSE: To retrospectively determine the incidence and outcome of angioplasty-induced ruptures that occurred during treatment of hemodialysis graft-related stenoses.

MATERIALS AND

METHODS

During a five year period 1222 patients with dysfunctional or thrombosed polytetrafluoroethylene (PTFE) hemodialysis grafts underwent angioplasty procedures at our institution. Angioplasty-induced vascular ruptures occurred in 24 (2.0%) patients. The locations of these ruptures were: basilic vein (10), venous anastomosis (7), cephalic vein (5), brachial vein (1) and intragraft (1). The mean length of the treated stenoses was 2.4 centimeters.

RESULTS

Manual compression was used to treat the vascular rupture in ten patients. One patient was treated with endovascular balloon tamponade and one patient underwent stenting of the rupture site. Despite the rupture, 15 patients had completion of the angioplasty procedure. In nine patients the procedure was abandoned due to persistent stenosis at the rupture site. There were no major complications as a result of these ruptures. Follow-up was available in ten of these patients. All ten underwent at least one successful hemodialysis treatment. In five of these patients the hemodialysis graft failed within 30 days after the rupture. The mean primary patency following rupture in the ten patients with follow-up was 87.5 days (range 5 - 225 days).

CONCLUSION

The incidence of angioplasty-induced vascular rupture of hemodialysis-related stenoses is low and despite the injury, the majority (62%) of procedures can be completed. However, in our experience the long-term patency of the vascular access was suboptimal.

Для цитирования: Pappas J N, Vesely T M. Vascular rupture during angioplasty of hemodialysis raft-related stenoses.. The journal of vascular access. 2002. DOI: 10.1177/112972980200300307.