DOI 10.1097/ftd.0000000000000890
Therapeutic Drug Monitoring of Lamotrigine, Lacosamide, and Levetiracetam in Dried Capillary Blood-Determination of Conversion Factors for Serum-Based Reference Ranges.
Аннотация
BACKGROUND
Drug concentrations of antiepileptic drugs (AEDs) are routinely determined from blood serum or plasma at trough levels (before intake of morning dose). In capillary blood collection, blood is taken from the fingertip with the aid of a disposable tool and dried on absorbent material. The volumetric absorptive microsampling technique offers several advantages over the use of filter paper cards. The aim of this study was to determine conversion factors for the estimation of AED serum concentrations from capillary blood concentrations.
METHODS
Venous and capillary blood samples were collected from adult inpatients with epilepsy who were treated with lacosamide (LCM, n = 30), lamotrigine (LTG, n = 40), and/or levetiracetam (LEV, n = 36). A validated liquid chromatography-mass spectrometry (LC-MS) method for dried blood samples for these AEDs was compared with routine serum laboratory methods. Method agreement was evaluated using different regression techniques, and the conversion factors were calculated.
RESULTS
Regression analyses revealed a linear relationship between serum and capillary blood concentrations for all 3 AEDs (r ≥ 0.95). For LTG, the regression intercept was significantly different from 0, indicating that the relationship was linear, but not necessarily proportional. Although LEV and LCM concentrations tended to be lower in capillary blood than in serum (mean ratio of serum concentration to capillary blood concentration: 1.14 and 1.22, respectively), LTG concentrations were higher in capillary blood (mean ratio = 0.85).
CONCLUSIONS
The estimation of serum concentrations from measured capillary blood concentrations is feasible for LCM, LTG, and LEV. A simple ratio approach using the mean ratio and Passing-Bablok regression showed the best results for all 3 AEDs. The volumetric absorptive microsampling technique facilitates the quantitative sample collection of capillary blood and overcomes the drawbacks associated with the classical dried blood spot technique.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.