MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1601-6343.2012.01550.x

Медицинская библиотека · Orthodontics & craniofacial research · 2012

Assessment of facial asymmetry in growing subjects with a three-dimensional laser scanning system.

Primozic J, Perinetti G, Zhurov A, Richmond S, Ovsenik M

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate facial asymmetry in growing subjects with no malocclusion on three-dimensional laser facial scans.

SETTING AND SAMPLE POPULATION: Twenty-seven healthy Caucasian children (15 boys and 12 girls, aged 5.4 ± 0.3 years) in the primary dentition without malocclusion were randomly selected from a local kindergarten in Slovenia.

MATERIAL AND

METHODS

Surface facial images were obtained using a three-dimensional laser scanning system at baseline and at 18, 30, 42 and 54 months of follow-up. Facial asymmetry was assessed quantitatively by measuring the average distance between facial image and mirrored image. Further, the percentage of asymmetry was calculated as the percentage of image to mirrored image not coinciding within 0.5 mm. Qualitative assessment was performed on colour deviation maps by recording the predominant side of the face for the upper, middle and lower parts of the face separately. Nonparametric tests were used for data analysis.

RESULTS

No face was perfectly symmetric. The average distance between the mirrored images for the whole face ranged 0.22-0.85 mm and the percentage of asymmetry 7.8-66.9. There were no significant gender differences (p > 0.05), and no significant change was found over the observed period. The upper part of the face was the least asymmetric, while the lower and middle parts showed similar degrees of asymmetry.

CONCLUSION

Facial asymmetry is already present at an early developmental stage and does not show any tendency to increase or decrease with growth in the pre-pubertal period.

Для цитирования: Primozic J, Perinetti G, Zhurov A, Richmond S, Ovsenik M. Assessment of facial asymmetry in growing subjects with a three-dimensional laser scanning system.. Orthodontics & craniofacial research. 2012. DOI: 10.1111/j.1601-6343.2012.01550.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.