UNLABELLED: Neuroendocrine tumors (NETs) are uncommon tumors with increasing incidence and prevalence. Current reports suggest that (68)Ga-DOTATATE PET/CT imaging improves diagnosis and staging of NETs compared with (111)In-DTPA-octreotide and conventional imaging. We performed a systematic review of (68)Ga-DOTATATE for safety and efficacy compared with octreotide and conventional imaging to determine whether available evidence supports U.S. Food and Drug Administration approval.

METHODS

Medline, EMBASE, Web of Science, and Cochrane Reviews electronic databases were searched from January 1999 to September 2015. Results were restricted to human studies comparing diagnostic accuracy of (68)Ga-DOTATATE with octreotide or conventional imaging for pulmonary or gastroenteropancreatic NET and for human studies reporting safety/toxicity for (68)Ga-DOTATATE with 10 subjects or more thought to have NETs. Direct communication with corresponding authors was attempted to obtain missing information. Abstracts meeting eligibility criteria were collected by a research librarian and assembled for reviewers; 2 reviewers independently determined whether or not to include each abstract. If either reviewer chose inclusion, the abstract was accepted for review.

RESULTS

Database and bibliography searches yielded 2,479 articles, of which 42 were eligible. Three studies compared the 2 radiopharmaceuticals in the same patient, finding (68)Ga-DOTATATE to be more sensitive than octreotide. Nine studies compared (68)Ga-DOTATATE with conventional imaging. (68)Ga-DOTATATE estimated sensitivity, 90.9% (95% confidence interval, 81.4%-96.4%), and specificity, 90.6% (95% confidence interval, 77.8%-96.1%), were high. Five studies were retained for safety reporting only. Report of harm possibly related to (68)Ga-DOTATATE was rare (6 of 974), and no study reported major toxicity or safety issues.

CONCLUSION

No direct comparison of octreotide and (68)Ga-DOTATATE imaging for diagnosis and staging in an unbiased population of NETs has been published. Available information in the peer-reviewed literature regarding diagnostic efficacy and safety supports the use of (68)Ga-DOTATATE for imaging of NETs where it is available.

Для цитирования: Deppen Stephen A, Blume Jeffrey, Bobbey Adam J, Shah Chirayu, Graham Michael M, Lee Patricia, Delbeke Dominique, Walker Ronald C. 68Ga-DOTATATE Compared with 111In-DTPA-Octreotide and Conventional Imaging for Pulmonary and Gastroenteropancreatic Neuroendocrine Tumors: A Systematic Review and Meta-Analysis.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2016. DOI: 10.2967/jnumed.115.165803.