MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/molecules25051248

Медицинская библиотека · Molecules (Basel, Switzerland) · 2020

On Column Binding a Real-Time Biosensor for β-lactam Antibiotics Quantification.

Abdullah Shahla M, Rachid Shwan

СтатьяПеревод в очереди

Аннотация

This work aimed to develop accurate, quick, and practical tools for the detection of residues of penicillin G antibiotic in biological and non-biological samples. The assays were developed based on the binding mechanism of β-lactam to penicillin-binding proteins; samples of different concentrations of penicillin G were incubated with in vitro expressed 6X-Histidine-tagged soluble penicillin-binding protein (PBP2x*) of Streptococcus pneumoniae (S. pneumoniae), whereby penicillin G in samples specifically binds to PBP2x*. The fluorescent-labeled β-lactam analogue Bocillin FL was used as a competent substrate, and two different routes estimated the amounts of the penicillin G. The first route was established based on the differences in the concentration of non-bounded Bocillin FL molecules within the reactions while using a real-time polymerase chain reaction (PCR)-based method for fluorescence detection. The second route depended on the amount of the relative intensity of Bocillin FL bounded to Soluble PBP-2x*, being run on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-page), visualized by a ChemiDoc-It®2 Imager, and quantified based on the fluorescence affinity of the competent substrate. While both of the methods gave a broad range of linearity and high sensitivity, the on column based real-time method is fast, non-time consuming, and highly sensitive. The method identified traces of antibiotic in the range 0.01-0.2 nM in addition to higher accuracy in comparison to the SDS-based detection method, while the sensitivity of the SDS-based method ranged between 0.015 and 2 µM). Thus, the on column based real time assay is a fast novel method, which was developed for the first time based on the binding inhibition of a fluorescence competitor material and it can be adapted to screen traces of penicillin G in any biological and environmental samples.

Для цитирования: Abdullah Shahla M, Rachid Shwan. On Column Binding a Real-Time Biosensor for β-lactam Antibiotics Quantification.. Molecules (Basel, Switzerland). 2020. DOI: 10.3390/molecules25051248.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.