MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0226627

Медицинская библиотека · PloS one · 2019

Clinical utility of mono-exponential model diffusion weighted imaging using two b-values compared to the bi- or stretched exponential model for the diagnosis of biliary atresia in infant liver MRI.

Kim Jisoo, Yoon Haesung, Lee Mi-Jung, Kim Myung-Joon, Han Kyunghwa, Han Seok Joo, Koh Hong, Kim Seung, Shin Hyun Joo

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the clinical utility of mono-exponential model diffusion weighted imaging (DWI) using two b-values compared to the bi- or stretched exponential model to differentiate biliary atresia (BA) from non-BA in pediatric liver magnetic resonance imaging (MRI).

METHODS

Patients who underwent liver MRI with DWI for suspected BA from November 2017 to September 2018 were retrospectively included and divided into BA and non-BA groups. Laboratory results including γ-glutamyl transferase (γGT) were compared between the two groups using the Mann-Whitney U test and Fisher's exact test. The hepatic apparent diffusion coefficient (ADC) 10 using ten b-values and ADC 2 using two b-values were obtained from the mono-exponential model. The slow diffusion coefficient (D), fast diffusion coefficient (D*), and perfusion fraction (f) were obtained from the bi-exponential model. The distributed diffusion coefficient (DDC) and heterogeneity index (α) were measured from the stretched exponential model. Parameters were compared between the two groups using a linear mixed model and diagnostic performance was assessed using the area under the curve (AUC) analysis.

RESULTS

For 12 patients in the BA and five patients in the non-BA group, the ADC 10 (median 0.985 ×10-3 mm2/s vs. 1.332 ×10-3 mm2/s, p = 0.008), ADC 2 (median 0.987 ×10-3 mm2/s vs. 1.335 ×10-3 mm2/s, p = 0.017), D* (median 33.2 ×10-3 mm2/s vs. 55.3 ×10-3 mm2/s, p = 0.021), f (median 13.4%, vs. 22.1%, p = 0.009), and DDC (median 0.889 ×10-3 mm2/s vs. 1.323 ×10-3 mm2/s, p = 0.009) values were lower and the γGT (median 368.0 IU/L vs. 93.5 IU/L, p = 0.02) and α (median 0.699 vs. 0.556, p = 0.023) values were higher in the BA group. The AUC values for γGT (AUC 0.867 95% confidence interval [CI] 0.616-0.984), ADC 10 (AUC 0.963, 95% CI 0.834-0.998), ADC 2 (AUC 0.925, 95% CI 0.781-0.987), f (AUC 0.850, 95% CI 0.686-0.949), and DDC (AUC 0.925, 95% CI 0.781-0.987) were not significantly different, except for the D* and α values.

CONCLUSION

Patients with BA had lower ADC 10, ADC 2, D*, f, and DDC values and higher γGT and α values than those in the non-BA group. The diagnostic performance of ADC 2 using only two b-values showed excellent diagnostic performance and was not significantly different from that of γGT, ADC 10, f, and DDC for diagnosing BA.

Для цитирования: Kim Jisoo, Yoon Haesung, Lee Mi-Jung, Kim Myung-Joon, Han Kyunghwa, Han Seok Joo, Koh Hong, Kim Seung, Shin Hyun Joo. Clinical utility of mono-exponential model diffusion weighted imaging using two b-values compared to the bi- or stretched exponential model for the diagnosis of biliary atresia in infant liver MRI.. PloS one. 2019. DOI: 10.1371/journal.pone.0226627.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.