Simplifying the Screening of Obstructive Sleep Apnea With a 2-Item Model, No-Apnea: A Cross-Sectional Study.

Duarte Ricardo L M, Rabahi Marcelo F, Magalhães-da-Silveira Flavio J, de Oliveira-E-Sá Tiago S, Mello Fernanda C Q, Gozal David

СтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

To develop and validate a practical model for obstructive sleep apnea (OSA) screening in adults based on objectively assessed criteria, and then compare it with two widely used tools, namely STOP-BANG and NoSAS.

METHODS

This is a retrospective study of an existing database of consecutive outpatients who were referred for polysomnography for suspected sleep-disordered breathing by their primary care physicians. Area under the curve (AUC) and 2 × 2 contingency tables were employed to obtain the performance of the new instrument.

RESULTS

A total of 4,072 subjects were randomly allocated into two independent cohorts: one for derivation (n = 2,037) and one for validation (n = 2,035). A mnemonic model, named No-Apnea, with two variables (neck circumference and age) was developed (total score: 0-9 points). We used the cutoff ≥ 3 to classify patients at high risk of having OSA. OSA severity was categorized by apnea-hypopnea index (AHI): any OSA (AHI 5 ≥ events/h; OSA-5), moderate/ severe OSA (AHI 15 ≥ events/h; OSA-15); and severe OSA (AHI 30 ≥ events/h; OSA-30). In the derivation cohort, the AUCs for screening of OSA-5, OSA-15, and OSA-30 were: 0.784, 0.758, and 0.754; respectively. The rate of subjects correctly screened was 78.1%, 68.8%, and 54.4%, respectively for OSA-5, OSA-15, and OSA-30. Subsequently, the model was validated confirming its reproducibility. In both cohorts, No-Apnea discrimination was similar to STOP-BANG or NoSAS.

CONCLUSIONS

The No-Apnea, a 2-item model, appears to be a useful and practical tool for OSA screening, mainly when limited resources constrain referral evaluation. Despite its simplicity when compared to previously validated tools (STOP-BANG and NoSAS), the instrument exhibits similar performance characteristics.

Для цитирования: Duarte Ricardo L M, Rabahi Marcelo F, Magalhães-da-Silveira Flavio J, de Oliveira-E-Sá Tiago S, Mello Fernanda C Q, Gozal David. Simplifying the Screening of Obstructive Sleep Apnea With a 2-Item Model, No-Apnea: A Cross-Sectional Study.. Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine. 2018. DOI: 10.5664/jcsm.7202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.