Prospective, multi-center evaluation of a silicon carbide coated cobalt chromium bare metal stent for percutaneous coronary interventions: two-year results of the ENERGY Registry.

Erbel Raimund, Eggebrecht Holger, Roguin Ariel, Schroeder Erwin, Philipp Sebastian, Heitzer Thomas, Schwacke Harald, Ayzenberg Oded, Serra Antonio, Delarche Nicolas, Luchner Andreas, Slagboom Ton, ENERGY Investigators

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Novel bare metal stents with improved stent design may become a viable alternative to drug-eluting stents in certain patient groups, particularly, when long-term dual antiplatelet therapy should be avoided.

PURPOSE: The ENERGY registry aimed to assess the safety and benefits of a cobalt-chromium thin strut bare metal stent with a passive coating in a large series of patients under real-world conditions.

METHODS AND MATERIALS: This prospective registry recruited 1016 patients with 1074 lesions in 48 centers from April to November 2010. The primary endpoint was the rate of major adverse cardiac events (MACEs), a composite of cardiac death, myocardial infarction and clinically driven target lesion revascularization.

RESULTS

More than half of the lesions (61.0%) were type A/B1 lesions, mean lesion length was 14.5±6.5mm and mean reference vessel diameter 3.2±0.5mm. MACE rates at 6, 12 and 24months were 4.9%, 8.1% and 9.4%, target lesion revascularization rates 2.8%, 4.9% and 5.4% and definite stent thrombosis rates 0.5%, 0.6% and 0.6%. Subgroups showed significant differences in baseline and procedural characteristics which did not translate into significantly different clinical outcomes. Specifically, MACE rates at 24months were 13.5% in diabetics, 8.6% in small stents and 9.6% in acute coronary syndrome patients.

CONCLUSION

The population of ENERGY reflects real-world conditions with bare metal stents being mainly used in simple lesions. In this setting, percutaneous coronary intervention using a cobalt-chromium thin strut bare metal stent with a passive coating showed very good results up to 24months. (ClinicalTrials.gov:NCT01056120) SUMMARY FOR ANNOTATED TABLE OF CONTENTS: The ENERGY international registry evaluated the safety and benefits of a cobalt-chromium thin strut bare metal stent with passive coating in 1016 patients under real-world conditions until 2years. Results were encouraging with a low composite rate of cardiac death, myocardial infarction and clinically driven target lesion revascularization, even in the pre-defined high risk groups of diabetes, stents ≤2.75mm and acute coronary syndrome.

Для цитирования: Erbel Raimund, Eggebrecht Holger, Roguin Ariel, Schroeder Erwin, Philipp Sebastian, Heitzer Thomas, Schwacke Harald, Ayzenberg Oded, Serra Antonio, Delarche Nicolas, Luchner Andreas, Slagboom Ton, ENERGY Investigators. Prospective, multi-center evaluation of a silicon carbide coated cobalt chromium bare metal stent for percutaneous coronary interventions: two-year results of the ENERGY Registry.. Cardiovascular revascularization medicine : including molecular interventions. 2014. DOI: 10.1016/j.carrev.2014.10.002.