MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1258/acb.2009.009002

Медицинская библиотека · Annals of clinical biochemistry · 2009

A rapid direct fluorescent assay for cell-free DNA quantification in biological fluids.

Goldshtein Hagit, Hausmann Michael J, Douvdevani Amos

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Circulating cell-free DNA (CFD) levels may be elevated in trauma, stroke, sepsis, pre-eclampsia and cancer. Owing to the complex and expensive methodology, detection of CFD has hitherto been confined to research laboratories. This study presents a simple, inexpensive and accurate test for CFD.

METHODS

Using the commercial fluorescent SYBR Gold stain, biological fluids were directly assayed for CFD without prior DNA extraction and amplification. Stain was added to the sample in 96-well plates (final stain dilution: 1:10,000) and fluorescence was read by a fluorometer (excitation wavelength 488 nm, emission wavelength 535 nm).

RESULTS

The assay was validated with serum, whole blood, urine and supernatant of cell cultures. Specificity and linearity were demonstrated over a wide range of concentrations; the results correlated with the conventional quantitative polymerase chain reaction assay of beta-globin (R(2) = 0.9987, P < 0.001). The assay was not affected by exposure of whole blood or serum to room temperature for four or 24 h, respectively. Intra and day-to-day coefficients of variation (16-4.8% and 31-8%, respectively; depending on DNA level) compared well with published data describing more work-intensive tests. The limit of quantitation (170 ng/mL) was below the mean DNA level in a cohort of normal individuals (471 [203] ng/mL). Finally, free DNA in supernatant of cell cultures after cell lysis accurately reflected cell number (R(2) = 0.974, P < 0.0001).

CONCLUSIONS

The direct SYBR Gold assay proved to be an accurate and simple technique for measuring CFD in biological fluids.

Для цитирования: Goldshtein Hagit, Hausmann Michael J, Douvdevani Amos. A rapid direct fluorescent assay for cell-free DNA quantification in biological fluids.. Annals of clinical biochemistry. 2009. DOI: 10.1258/acb.2009.009002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.