MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1302/0301-620x.98b3.36730

Медицинская библиотека · The bone & joint journal · 2016

Do large pragmatic randomised trials change clinical practice?: assessing the impact of the Distal Radius Acute Fracture Fixation Trial (DRAFFT).

Costa M L, Jameson S S, Reed M R

СтатьяПеревод в очереди

Аннотация

AIMS: Our aim, using English Hospital Episode Statistics data before during and after the Distal Radius Acute Fracture Fixation Trial (DRAFFT), was to assess whether the results of the trial affected clinical practice.

PATIENTS AND

METHODS

Data were grouped into six month intervals from July 2005 to December 2014. All patient episodes in the National Health Service involving emergency surgery for an isolated distal radial fracture were included.

RESULTS

Clinical practice in England had not changed in the five years before DRAFFT: 75% of patients were treated with plate fixation versus 12% with Kirschner (K)-wires. After the publication of the trial, the proportion of patients having K-wire fixation rose to 42% with a concurrent fall in the proportion having fixation with a plate to 48%. The proportion of 'other' procedures stayed the same.

TAKE HOME MESSAGE: It appears that surgeons in the United Kingdom do change their practice in response to large, pragmatic, multicentre clinical trials in musculoskeletal trauma.

Для цитирования: Costa M L, Jameson S S, Reed M R. Do large pragmatic randomised trials change clinical practice?: assessing the impact of the Distal Radius Acute Fracture Fixation Trial (DRAFFT).. The bone & joint journal. 2016. DOI: 10.1302/0301-620x.98b3.36730.