MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2025.129054

Медицинская библиотека · Talanta · 2025

Truncated PNA-functionalized porous silicon biosensor for low-cost and early detection of troponin T in myocardial infarction.

Nolli Maria Grazia, Bartocci Alessio, De Rosa Caterina, Falanga Andrea Patrizia, Abbate Vincenzo, Terracciano Monica, Nocerino Valeria, Rea Ilaria, De Stefano Luca, Giordano Sabrina, Piccialli Gennaro, Costantino Marco Fabio, Della Corte Carminia Maria, Dumont Elise, Borbone Nicola, Dell'Aversana Giovanni Orabona, Oliviero Giorgia

СтатьяПеревод в очереди

Аннотация

A label-free optical biosensor based on porous silicon (PSi) was developed for the high-sensitivity detection of human cardiac troponin T (cTnT), a key biomarker for the early diagnosis of myocardial infarction (MI). To reduce synthesis costs while maintaining binding efficiency, a truncated peptide nucleic acid (PNA) probe was designed in silico starting from a 40-base-long wild-type sequence. Computational screening identified a 12-base candidate, whose binding affinity was experimentally validated by Western blot analysis. The freshly etched PSi surface was passivated and functionalized via mild thermal hydrosilylation with 10-undecenoic acid to introduce carboxylic groups, enabling covalent PNA immobilization through the carbodiimide chemistry. Surface functionalization and stability in aqueous media were validated using both label-free optical reflectance and fluorescence spectroscopy. Probe conjugation was optimized at pH 5.5, resulting in a surface density of 1.12 ± 0.30 pmol cm-2. The biosensor exhibited reproducible, concentration-dependent responses to cTnT in the 0.02-0.16 ng mL-1 range, with a limit of detection of 0.030 ± 2.0 × 1 0 -5 ng mL-1. This performance is clinically relevant, as cTnT levels in healthy individuals are typically <0.01 ng mL-1, while MI patients often exceed 10 ng mL-1, reaching >100 ng mL-1 in severe cases.

Для цитирования: Nolli Maria Grazia, Bartocci Alessio, De Rosa Caterina, Falanga Andrea Patrizia, Abbate Vincenzo, Terracciano Monica, Nocerino Valeria, Rea Ilaria, De Stefano Luca, Giordano Sabrina, Piccialli Gennaro, Costantino Marco Fabio, Della Corte Carminia Maria, Dumont Elise, Borbone Nicola, Dell'Aversana Giovanni Orabona, Oliviero Giorgia. Truncated PNA-functionalized porous silicon biosensor for low-cost and early detection of troponin T in myocardial infarction.. Talanta. 2025. DOI: 10.1016/j.talanta.2025.129054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.