MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10140-018-1658-z

Медицинская библиотека · Emergency radiology · 2018

Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.

Moloney Fiachra, James Karl, Twomey Maria, Ryan David, Grey Tyler M, Downes Amber, Kavanagh Richard G, Moore Niamh, Murphy Mary Jane, Bye Jackie, Carey Brian W, McSweeney Sean E, Deasy Conor, Andrews Emmett, Shanahan Fergus, Maher Michael M, O'Connor Owen J

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Performance of a modified abdominopelvic CT protocol reconstructed using full iterative reconstruction (IR) was assessed for imaging patients presenting with acute abdominal symptoms.

MATERIALS AND

METHODS

Fifty-seven patients (17 male, 40 female; mean age of 56.5 ± 8 years) were prospectively studied. Low-dose (LD) and conventional-dose (CD) CTs were contemporaneously acquired between November 2015 and March 2016. The LD and CD protocols imparted radiation exposures approximating 10-20% and 80-90% those of routine abdominopelvic CT, respectively. The LD images were reconstructed with model-based iterative reconstruction (MBIR), and CD images with hybrid IR (40% adaptive statistical iterative reconstruction (ASIR)). Image quality was assessed quantitatively and qualitatively. Independent clinical interpretations were performed with a 6-week delay between reviews.

RESULTS

A 74.7% mean radiation dose reduction was achieved: LD effective dose (ED) 2.38 ± 1.78 mSv (size-specific dose estimate (SSDE) 3.77 ± 1.97 mGy); CD ED 7.04 ± 4.89 mSv (SSDE 10.74 ± 5.5 mGy). LD-MBIR images had significantly lower objective and subjective image noise compared with CD-ASIR (p < 0.0001). Noise reduction for LD-MBIR studies was greater for patients with BMI < 25 kg/m2 than those with BMI ≥ 25 kg/m2 (5.36 ± 3.2 Hounsfield units (HU) vs. 4.05 ± 3.1 HU, p < 0.0001). CD-ASIR studies had significantly better contrast resolution, and diagnostic acceptability (p < 0.0001 for all). LD-MBIR studies had significantly lower streak artifact (p < 0.0001). There was no difference in sensitivity for primary findings between the low-dose and conventional protocols with the exception of one case of enteritis.

CONCLUSIONS

Low-dose abdominopelvic CT performed with MBIR is a feasible radiation dose reduction strategy for imaging patients presenting with acute abdominal pain.

Для цитирования: Moloney Fiachra, James Karl, Twomey Maria, Ryan David, Grey Tyler M, Downes Amber, Kavanagh Richard G, Moore Niamh, Murphy Mary Jane, Bye Jackie, Carey Brian W, McSweeney Sean E, Deasy Conor, Andrews Emmett, Shanahan Fergus, Maher Michael M, O'Connor Owen J. Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.. Emergency radiology. 2018. DOI: 10.1007/s10140-018-1658-z.