MedElevator Войти в исследования
← Поиск публикаций
Respiration; international review of thoracic diseases · 2018

Ventilation Parameters under Adaptive Servo Ventilation: A Comparison on Behalf of CSA-Pattern, BNP/NT-pro-BNP, and Ejection Fraction.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Westhoff Michael, Litterst Patric

Аннотация

BACKGROUND: The SERVE-HF study has raised questions concerning the higher mortality under adaptive servoventilation. The ventilatory mode was discussed as a possible aggravating factor.

OBJECTIVES: We wondered if the data recorded by the adaptive servo-ventilation (ASV)-devices in heart failure patients with CSA-CSR ± OSA are different in terms of respiratory parameters and therapeutic pressures compared to patients with CPAP-resistant/emergent-CSA with normal BNP/NT-pro-BNP.

METHODS: Patients were included, if ASV had normalized respiratory disturbance index in the first night of application and after at least 6 weeks. ASV-device data were analyzed in terms of respiratory rate (RR), min ventilation (MV), endexpiratory (EEP), peak inspiratory pressure (Ppeak) and median pressure.

RESULTS: Compared to CPAP-resistant/emergent-CSA with normal BNP/NT-pro-BNP (n = 25), CSA-CSR- (n = 13) CSA-CSR+OSA-patients (n = 32) with elevated BNP/NT-pro-BNP had higher RR (p < 0.01) in the first night of ASV therapy and during follow-up (15.3 ± 1.3 vs. 17.3 ± 2.4/min) with similar MV (6.5 ± 1.3 vs. 6.6 ± 1.3 L), resulting in significantly lower tidal volumes. EEP (5.6 ± 1.1 vs. 5.5 ± 1.1 hPa), Pmedian and Ppeak (9.8 ± 1.5 vs. 9.7 ± 1.2 hPa) were comparable. Ventilatory parameters were not different between LVEF < 40, 40-49, and ≥50%, neither within the whole group nor the group of CSA-CSR ± OSA and heart failure.

CONCLUSION: Patients with heart failure and CSA-CSR ± OSA have higher RRs but similar MV under ASV-therapy than patients with CSA and normal BNP. This indicates higher dead space ventilation. EF was not found to have an influence on the ventilatory parameters.

Предметные рубрики MeSH