MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sleep.2019.05.019

Медицинская библиотека · Sleep medicine · 2019

Effect of continuous positive airway pressure on respiratory drive in patients with obstructive sleep apnea.

Radovanovic Dejan, Rizzi Maurizio, Airoldi Andrea, Mantero Marco, Di Marco Fabiano, Raccanelli Rita, Santus Pierachille

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Patients with obstructive sleep apnea (OSA) have an altered control of breathing during wakefulness. Thus far, whether and how treatment with continuous positive airway pressure (CPAP) may restore these abnormalities has been poorly understood. The aim of this study was to investigate the long-term effects of CPAP on the breathing pattern, ventilatory drive (VDr), and chemoreceptor sensitivity in OSA patients.

PATIENTS AND

METHODS

This was a prospective, observational study, carried out in an academic sleep outpatient clinic. A total of 62 patients with OSA (mean age [SD], 51 [11] years) underwent polysomnography (PSG), breathing pattern assessment, mouth occlusion pressure, ventilatory response to hypoxemia (Ve/SaO2), and hypercapnia (Ve/PETCO2) before and after CPAP titration and during 12-month follow-up. A total of 48 age-matched healthy subjects served as controls. Patients with good (≥6 h/night) and poor (<6 h/night) compliance with CPAP were also compared.

RESULTS

At baseline, VDr as well as thoracic and inspiratory impedances were greater in patients with OSA compared with controls and were reduced by CPAP treatment, starting from the night of titration (P < 0.01), especially in patients with good compliance with CPAP. Baseline Ve/SaO2 was higher in OSA patients (P < 0.05) and was progressively normalized during CPAP treatment (P < 0.001). The pathophysiological changes were mainly due to a reduction in tidal volume. The remaining breathing pattern parameters were unaltered by CPAP treatment and were similar between groups.

CONCLUSION

In OSA patients, the mechanics of breathing are inefficient because of an imbalance of the VDr. Regular CPAP treatment improves the efficiency of the respiratory system and normalizes the hypoxemic stimulus.

Для цитирования: Radovanovic Dejan, Rizzi Maurizio, Airoldi Andrea, Mantero Marco, Di Marco Fabiano, Raccanelli Rita, Santus Pierachille. Effect of continuous positive airway pressure on respiratory drive in patients with obstructive sleep apnea.. Sleep medicine. 2019. DOI: 10.1016/j.sleep.2019.05.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.