Radiofrequency Ablation with an Internally Cooled Electrode for Twin Reversed Arterial Perfusion Sequence.

Wagata Maiko, Murakoshi Takeshi, Ishii Keisuke, Muromoto Jin, Sasahara Jun, Murotsuki Jun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The study aims to evaluate the efficacy of radiofrequency ablation (RFA) with an internally cooled electrode for twin reversed arterial perfusion (TRAP) sequence.

METHODS

From April 2008 through December 2014, we retrospectively reviewed all patients who underwent RFA with an internally cooled electrode for TRAP sequence at 3 tertiary referral centers in Japan.

RESULTS

Twenty-five monochorionic diamniotic twin pregnancies underwent RFA with an internally cooled electrode for TRAP sequence at 16-27 weeks of gestation. In all cases, umbilical cord blood flow cessation in the acardiac twin was confirmed by ultrasonography with color Doppler. There were 2 cases of procedure-related complications: 1 case of unintentional septostomy and 1 case of anemia in a pump twin. Fetal demise of the pump twin occurred in 3 (12%) cases. Twenty-two (88%) of 25 pump twins were delivered alive. The median gestational age at delivery was 36 + 3 weeks (range 25 + 2-40 + 5 weeks). There were 14 cases (64%) of premature deliveries before 37 weeks and 5 (23%) before 32 weeks.

CONCLUSION

RFA with an internally cooled electrode is a feasible and effective procedure for the treatment of TRAP sequence.

Для цитирования: Wagata Maiko, Murakoshi Takeshi, Ishii Keisuke, Muromoto Jin, Sasahara Jun, Murotsuki Jun. Radiofrequency Ablation with an Internally Cooled Electrode for Twin Reversed Arterial Perfusion Sequence.. Fetal diagnosis and therapy. 2016. DOI: 10.1159/000442152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.