Single-walled carbon nanotube biosensor for real-time monitoring of nitric oxide in inflammatory responses.

Zubkovs Vitalijs, Belcastro Laura, Sajjadi Sayyed Hashem, Rabbani Yahya, Ristaniemi Aapo, Mdingi Vuyisa, Peez Christian, Tognato Riccardo, Serra Tiziano, Cattaneo Stefano, Grad Sibylle, Boghossian Ardemis A, Basoli Valentina

СтатьяПеревод в очереди

Аннотация

Osteoarthritis (OA) is a degenerative inflammatory joint disease affecting millions of people worldwide. The early detection of OA and the continuous monitoring of its progression are essential for managing the disease. In this study, we develop an optical system for monitoring OA-related inflammation by detecting nitric oxide (NO), a molecule that is overproduced in joints during OA. The NO sensor is based on fluorescent single-walled carbon nanotubes (SWCNTs) coated with single-stranded DNA (ssDNA). The sensor fluorescence was characterized in the presence of cells and biological tissue using a custom-built optical shortwave infrared (SWIR) reader with LED excitation centered at 657 nm and 726 nm and emissions collected above 1000 nm. The ssDNA-SWCNTs were embedded in gelatin methacryloyl (GelMA) hydrogels to monitor the release of NO in inflamed (1 ng/mL IL1β) bovine chondrocytes over 48 h. The sensors show a concentration-dependent mechanical stability, maintaining a stable Young's modulus for at least 30 days at 1:10 ssDNA-SWCNT:GelMA mixing ratios (17.8 mg/L SWCNTs). The sensor was incorporated into a custom microfabricated sensor tag that was surgically inserted ex vivo into bovine and human knees. The reader measurements confirm measurable SWIR signal depths of up to 6 mm under the skin and 6 mm under muscle tissue. The measurements further confirm no significant sensor tag displacement after 2500 flexion knee cycles. The custom ssDNA-SWCNT sensor tag and reader thus demonstrate a potential pathway for integrating SWIR technologies into clinical and orthopedic applications.

Для цитирования: Zubkovs Vitalijs, Belcastro Laura, Sajjadi Sayyed Hashem, Rabbani Yahya, Ristaniemi Aapo, Mdingi Vuyisa, Peez Christian, Tognato Riccardo, Serra Tiziano, Cattaneo Stefano, Grad Sibylle, Boghossian Ardemis A, Basoli Valentina. Single-walled carbon nanotube biosensor for real-time monitoring of nitric oxide in inflammatory responses.. Biosensors & bioelectronics. 2025. DOI: 10.1016/j.bios.2025.118092.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.