MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/ejo.5000365

Медицинская библиотека · European journal of ophthalmology · 2013

Clear lens phacoemulsification in Alport syndrome: refractive results and electron microscopic analysis of the anterior lens capsule.

Bayar Sezin Akca, Pinarci Eylem Yaman, Karabay Gulten, Akman Ahmet, Oto Sibel, Yilmaz Gursel

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group.

METHODS

Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were included in this study. Clear corneal phacoemulsification and intraocular foldable lens implantation was performed in eyes with indeterminate refractive errors and/or poor visual acuity and anterior capsule samples were analyzed with electron microscopy.

RESULTS

All patients had a history of hereditary nephritis and/or deafness as systemic involvement. Ophthalmologic examination revealed anterior lenticonus with high myopia and/or irregular astigmatism in all patients. The mean best-corrected visual acuity (BCVA) was 0.67 ± 0.17 logMAR (range 1.0-0.4) preoperatively and 0.17 ± 0.08 logMAR (range 0.3-0.0) postoperatively. Postoperative refractive lenticular astigmatism dramatically decreased and no ocular complications arose during the follow-up period. Transmission electron microscopic analysis of the lens capsules supported the diagnosis of Alport syndrome.

CONCLUSIONS

Clear lens phacoemulsification and foldable intraocular lens implantation is a safe and effective therapeutic choice for the management of uncorrectable refractive errors and low visual acuity due to anterior lenticonus in patients with Alport syndrome.

Для цитирования: Bayar Sezin Akca, Pinarci Eylem Yaman, Karabay Gulten, Akman Ahmet, Oto Sibel, Yilmaz Gursel. Clear lens phacoemulsification in Alport syndrome: refractive results and electron microscopic analysis of the anterior lens capsule.. European journal of ophthalmology. 2013. DOI: 10.5301/ejo.5000365.