MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2013.02.007

Медицинская библиотека · Academic radiology · 2013

Interreader scoring variability in an observer study using dual-modality imaging for breast cancer detection in women with dense breasts.

Drukker Karen, Horsch Karla J, Pesce Lorenzo L, Giger Maryellen L

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

To evaluate variability in the clinical assessment of breast images, we evaluated scoring behavior of radiologists in a retrospective reader study combining x-ray mammography (XRM) and three-dimensional automated breast ultrasound (ABUS) for breast cancer detection in women with dense breasts.

METHODS

The study involved 17 breast radiologists in a sequential study design with readers first interpreting XRM-alone followed by an interpretation of combined XRM + ABUS. Each interpretation included a forced Breast Imaging Reporting and Data System scale and a likelihood that the woman had breast cancer. The analysis included 164 asymptomatic patients, including 31 breast cancer patients, with dense breasts and a negative screening XRM. Of interest were interreader scoring variability for XRM-alone, XRM + ABUS, and the sequential effect. In addition, a simulated double reading by pairs of readers of XRM + ABUS was investigated. Performance analysis included receiver operating characteristic analysis, percentile analysis, and κ statistics. Bootstrapping was used to determine statistical significance.

RESULTS

The median change in area under the receiver operating characteristic curve after ABUS interpretation was 0.12 (range 0.04-0.19). Reader agreement was fair with the median interreader κ being 0.26 (0.05-0.48) for XRM-alone and 0.34 (0.11-0.55) for XRM + ABUS (95% confidence interval for the difference in κ, 0.06-0.11). Simulated double reading of XRM + ABUS demonstrated tradeoffs in sensitivity and specificity, but conservative simulated double reading resulted in a significant improvement in both sensitivity (16.7%) and specificity (7.6%) with respect to XRM-alone.

CONCLUSION

A modest, but statistically significant, increase in interreader agreement was observed after interpretation of ABUS.

Для цитирования: Drukker Karen, Horsch Karla J, Pesce Lorenzo L, Giger Maryellen L. Interreader scoring variability in an observer study using dual-modality imaging for breast cancer detection in women with dense breasts.. Academic radiology. 2013. DOI: 10.1016/j.acra.2013.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.