MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2024.11.013

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2024

Association Between Pulmonary Artery Pulsatility Index and Radial Artery Pulse Pressure and Successful Separation from Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation: A French Single-Center Retrospective Study From 2017 to 2021.

Duong Viet-Dung, Aludaat Chadi, Kouadri Geoffrey, Scherrer Vincent, Clavier Thomas, Demailly Zoe, Compère Vincent, Rey Nathalie, Selim Jean, Besnier Emmanuel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Few reliable tools exist to predict weaning patient outcomes from venoarterial extracorporeal membrane oxygenation (ECMO; VA-ECMO). Pulmonary artery pulse pressure indexed on right atrial pressure (PAPi) reflects the ventricle-pulmonary coupling and may be representative of right ventricular recovery. Radial artery pulse pressure (rPP) may be representative of left ventricular recovery. We intended to explore the usefulness of these indices in the weaning from VA-ECMO.

DESIGN

Retrospective cohort study.

SETTING

Single center in a tertiary university hospital.

PARTICIPANTS

Patients benefiting from a VA-ECMO for all-cause refractory cardiogenic shock between 2017 and 2021. Non-inclusion criteria were minor/pregnant patients and ECMO within 48 hours. Univariate and multivariate logistic regression analyses explored the relationship between PAPi and rPP with weaning success.

INTERVENTIONS: We explored the association between the pulmonary artery pulse pressure indexed on PAPi, rPP, and the success of weaning from VA-ECMO.

MEASUREMENTS AND MAIN

RESULTS

We included 124 patients for rPP analysis and 82 patients for PAPi analysis. Higher rPP and PAPi (50.43 v 26.3 mmHg, p < 0.001: 1.78 v 0.88, p < 0.001, respectively) and shorter ECMO duration were associated with weaning success. Areas under ROC for rPP and PAPi were 0.85 and 0.88. The combination of rPP ≥ 40 mmHg and PAPi ≥ 1.09 predicted weaning with a sensitivity of 0.94, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.84.

CONCLUSION

Higher PAPi and rPP were predictors of successful weaning from VA-ECMO in this retrospective study.

Для цитирования: Duong Viet-Dung, Aludaat Chadi, Kouadri Geoffrey, Scherrer Vincent, Clavier Thomas, Demailly Zoe, Compère Vincent, Rey Nathalie, Selim Jean, Besnier Emmanuel. Association Between Pulmonary Artery Pulsatility Index and Radial Artery Pulse Pressure and Successful Separation from Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation: A French Single-Center Retrospective Study From 2017 to 2021.. Journal of cardiothoracic and vascular anesthesia. 2024. DOI: 10.1053/j.jvca.2024.11.013.