MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neurom.2026.01.001

Медицинская библиотека · Neuromodulation : journal of the International Neuromodulation Society · 2026

Electrophysiologic Characteristics of Epidural Spinal Signals in Preclinical Models of Spinal Cord Stimulation.

Ladner Kimberley, Versantvoort Eline M, Thijssen Marjolein E G, Mugan Dave, Baker Stuart N, Kraskov Alexander, Vuong Quoc C, Sharma Mahima, Bikson Marom, Dietz Birte E, Palmisani Stefano, Obara Ilona

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Epidural stimulation of the spinal cord evokes distinct electrophysiologic responses that can be recorded epidurally. Here, we characterized evoked compound action potentials (ECAPs), doublets (secondary or tertiary ECAPs, probably of different physiologic origin from primary ECAPs), evoked synaptic activity potentials (ESAPs), and electromyographic (EMG) signals in preclinical models. Our objective was to clarify the features and distinct physiologic origins of these signals, to advance mechanistic studies and support clinical applications of spinal cord stimulation (SCS) therapy.

MATERIALS AND

METHODS

Adult male Sprague-Dawley rats (300-440 g) were implanted with two epidural leads (caudal and rostral; each with eight electrodes) and received monopolar, biphasic stimulation (200-μs pulse width) at 2 and 50 Hz, with current increased stepwise to motor threshold. Rhesus macaques (11.5 and 10.2 kg) were implanted with a single 12-electrode epidural lead and stimulated using either tripolar, triphasic pulses at 10 Hz (100 μs) or tripolar, biphasic pulses at 3 Hz (80 μs) up to 3 × ECAP threshold. Recordings were taken from nonstimulating electrodes.

RESULTS

ECAPs and EMG signals were recorded across multiple spinal segments in both rats (L1-T7) and macaques (L2-T11). Doublets presented as complex waveforms with multiple negative peaks, two in rats and three in macaques, likely representing distinct ECAPs at T11-T6 in a rat and L1-T11 in macaques. ESAPs, detectable in rats, showed anatomical specificity over the L1/T13 vertebrae, with peak responses at L1. Signal analysis included activation thresholds, amplitudes, latencies, and conduction velocities.

CONCLUSIONS

This study outlines electrophysiologic signals evoked by SCS in terms of their waveform, recruitment thresholds, and putative physiologic origins. We propose that to some extent, these signals reflect different aspects of spinal processing and may serve as biomarkers of dysregulated nociceptive pathways, and as indicators of SCS efficacy or potential side effects.

Для цитирования: Ladner Kimberley, Versantvoort Eline M, Thijssen Marjolein E G, Mugan Dave, Baker Stuart N, Kraskov Alexander, Vuong Quoc C, Sharma Mahima, Bikson Marom, Dietz Birte E, Palmisani Stefano, Obara Ilona. Electrophysiologic Characteristics of Epidural Spinal Signals in Preclinical Models of Spinal Cord Stimulation.. Neuromodulation : journal of the International Neuromodulation Society. 2026. DOI: 10.1016/j.neurom.2026.01.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.