DOI 10.1016/j.jmsacl.2022.12.003

Медицинская библиотека · Journal of mass spectrometry and advances in the clinical lab · 2022

Validation of a quantitative multiplex LC-MS/MS assay of carvedilol, enalaprilat, and perindoprilat in dried blood spots from heart failure patients and its cross validation with a plasma assay.

Joubert Andre, Joubert Anton, van der Merwe Marthinus, Norman Jennifer, Castel Sandra, Denti Paolo, Sliwa Karen, Maartens Gary, Sinxadi Phumla, Wiesner Lubbe

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Adherence to medication is an important determinant of outcomes in chronic diseases like heart failure. Drug assays provide objective adherence biomarkers. Dried blood spots (DBS) are appealing samples for drug assays due to less demanding transportation and storage requirements.

OBJECTIVES

To analytically validate a LC-MS/MS method for the simultaneous quantification of carvedilol, enalaprilat, and perindoprilat in DBS and evaluate the feasibility of using the method as an adherence determining assay. To validate the assay further clinically by establishing correlation and agreement between plasma and DBS samples from a pharmacokinetic pilot study.

METHODS

The method was validated over a concentration range of 1.00-200 ng/mL according to FDA guidelines. Adherence tracking ability of the assay was evaluated using a pharmacokinetic pilot study. Correlation and agreement were evaluated through Deming regression and Bland-Altman analysis, respectively.

RESULTS

Accuracy, precision, selectivity, and sensitivity were proven with complete and reproducible extraction recovery at all concentrations tested. Stability of the analytes in the matrix and throughout sample processing was proven. The full range of concentrations of the pharmacokinetic pilot study could be quantified for enalaprilat, but not for carvedilol and perindoprilat. The difference between the observed and calculated plasma concentrations was less than 20 % of their mean for >67 % of samples for all analytes.

CONCLUSIONS

The assay is suitable as a screening tool for carvedilol and perindoprilat, while suitable as an adherence determining assay for enalaprilat. Equivalence between observed and predicted plasma concentrations proves DBS and plasma concentrations can be used interchangeably.

Для цитирования: Joubert Andre, Joubert Anton, van der Merwe Marthinus, Norman Jennifer, Castel Sandra, Denti Paolo, Sliwa Karen, Maartens Gary, Sinxadi Phumla, Wiesner Lubbe. Validation of a quantitative multiplex LC-MS/MS assay of carvedilol, enalaprilat, and perindoprilat in dried blood spots from heart failure patients and its cross validation with a plasma assay.. Journal of mass spectrometry and advances in the clinical lab. 2022. DOI: 10.1016/j.jmsacl.2022.12.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.