MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2011.06.027

Медицинская библиотека · Analytica chimica acta · 2011

Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals.

Zhao Hongwei, Nan Tiegui, Tan Guiyu, Gao Wei, Cao Zhen, Sun Shuo, Li Zhaohu, Li Qing X, Wang Baomin

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules.

Для цитирования: Zhao Hongwei, Nan Tiegui, Tan Guiyu, Gao Wei, Cao Zhen, Sun Shuo, Li Zhaohu, Li Qing X, Wang Baomin. Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals.. Analytica chimica acta. 2011. DOI: 10.1016/j.aca.2011.06.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.