Impact of thoracic endovascular aortic repair following blunt traumatic thoracic aortic injury on blood pressure.

Guala Andrea, Gil-Sala Daniel, Garcia Reyes Marvin E, Azancot Maria A, Dux-Santoy Lydia, Allegue Allegue Nicolas, Teixido-Turà Gisela, Goncalves Martins Gabriela, Galian-Gay Laura, Garrido-Oliver Juan, Constenla García Ivan, Evangelista Arturo, Tello Díaz Cristina, Carrasco-Poves Alejandro, Morales-Galán Alberto, Ferreira-González Ignacio, Rodríguez-Palomares Jose, Bellmunt Montoya Sergi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Blunt traumatic thoracic aortic injuries (BTAIs) are associated with a high mortality rate. Thoracic endovascular aortic repair (TEVAR) is the most frequently used surgical strategy in patients with BTAI, as it offers good short- and middle-term results. Previous studies have reported an abnormally high prevalence of hypertension (HT) in these patients. This work aimed to describe the long-term prevalence of HT and provide a comprehensive evaluation of the biomechanical, clinical, and functional factors involved in HT development.

METHODS

Twenty-six patients treated with TEVAR following BTAI with no history of HT at the time of trauma were enrolled. They were matched with 37 healthy volunteers based on age, sex, and body surface area and underwent a comprehensive follow-up study, including cardiovascular magnetic resonance, 24-hour ambulatory blood pressure monitoring, and assessment of carotid-femoral pulse wave velocity (cfPWV, a measure of aortic stiffness) and flow-mediated vasodilation.

RESULTS

The mean patient age was 43.5 ± 12.9 years, and the majority were male (23 of 26; 88.5%). At a mean of 120.2 ± 69.7 months after intervention, 17 patients (65%) presented with HT, 14 (54%) had abnormal nighttime blood pressure dipping, and 6 (23%) high cfPWV. New-onset HT was related to a more proximal TEVAR landing zone and greater distal oversizing. Abnormal nighttime blood pressure was related to high cfPWV, which in turn was associated with TEVAR length and premature arterial aging.

CONCLUSIONS

HT frequently occurs otherwise healthy subjects undergoing TEVAR implantation after BTAI. TEVAR stiffness and length, the proximal landing zone, and distal oversizing are potentially modifiable surgical characteristics related to abnormal blood pressure.

Для цитирования: Guala Andrea, Gil-Sala Daniel, Garcia Reyes Marvin E, Azancot Maria A, Dux-Santoy Lydia, Allegue Allegue Nicolas, Teixido-Turà Gisela, Goncalves Martins Gabriela, Galian-Gay Laura, Garrido-Oliver Juan, Constenla García Ivan, Evangelista Arturo, Tello Díaz Cristina, Carrasco-Poves Alejandro, Morales-Galán Alberto, Ferreira-González Ignacio, Rodríguez-Palomares Jose, Bellmunt Montoya Sergi. Impact of thoracic endovascular aortic repair following blunt traumatic thoracic aortic injury on blood pressure.. The Journal of thoracic and cardiovascular surgery. 2023. DOI: 10.1016/j.jtcvs.2023.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.