Stress distribution in mandibular donor site after harvesting bone grafts of various sizes from the ascending ramus of a dentate mandible by finite element analysis.

Möhlhenrich Stephan Christian, Kniha Kristian, Szalma József, Ayoub Nassim, Hölzle Frank, Wolf Michael, Modabber Ali, Raith Stefan

СтатьяПеревод в очереди

Аннотация

PURPOSE: Harvesting bone from the ascending ramus of the mandible is a common procedure. However, mandibular fracture may occur after grafting bone blocks. This study aimed to investigate the resulting force distribution of stress and strain in the mandibular donor site after harvesting bone grafts of different sizes and various loadings.

METHODS

Finite element analysis was performed for virtual harvesting of bone blocks of nine different sizes between 15 × 20 and 25 × 30 mm and three different chewing loads (incisal, ipsilateral and contralateral). von Mises stress and first principal stress distributions were measured.

RESULTS

von Mises stress was distributed between 35.01 (10 × 15 mm graft, incisal load) and 333.25 MPa (30 × 20 mm graft ipsilateral load), whereas first principal stress distributions were between 48.27 (10 × 15 mm graft, incisal load) and 414.69 MPa (30 × 20 mm graft ipsilateral load). In general, the least stress was observed with incisal load followed by ipsilateral load and finally contralateral load. The critical value of 133 MPa was found after removing almost all grafts with a width of 20 or 30 mm.

CONCLUSIONS

Incisal loading led to less stress compared with contralateral and ipsilateral loads. Increasing graft size led to increasing weakness of the donor site. Graft width exerted a greater influence on stress development than its height.

CLINICAL RELEVANCE: Ipsilateral chewing and increasing width of the bone graft result in maximum stress in the mandibular donor side, and critical values regarding to the possibility of fractures are already to expect from a graft size of 20 × 15 mm.

Для цитирования: Möhlhenrich Stephan Christian, Kniha Kristian, Szalma József, Ayoub Nassim, Hölzle Frank, Wolf Michael, Modabber Ali, Raith Stefan. Stress distribution in mandibular donor site after harvesting bone grafts of various sizes from the ascending ramus of a dentate mandible by finite element analysis.. Clinical oral investigations. 2018. DOI: 10.1007/s00784-018-2671-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.