MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adma.75093

Медицинская библиотека · Advanced materials (Deerfield Beach, Fla.) · 2026

Perovskite Photodetectors With Customizable Frequency Response.

Yang Siping, Zhang Jiaqing, Sun Haoxuan, Zhou Yicheng, Zhang Chi, Yang Tianrun, Huang Yongrong, Min Liangliang, Cao Fengren, Li Liang

СтатьяПеревод в очереди

Аннотация

Photodetectors in emerging optoelectronic systems are increasingly required to deliver application-defined transfer characteristics rather than merely high responsivity or fast response. Existing response-engineering strategies mainly operate in the wavelength or intensity domains, but often increase source-side complexity, power consumption, and sensitivity to optical-path fluctuations. Here we introduce a frequency-centric strategy for response modulation. By combining a time-integrated-charge-based alternating-current-to-direct-current (AC-DC) mapping with continuous tuning of the built-in electric fields across heterojunction regions with antagonistic photoresponses, the transfer function becomes customizable in the frequency domain. Using lead-halide perovskites as a model platform, we demonstrate bipolar responses for image-processing, nonlinear responses for neuromorphic activation-function emulation, and selective responses for anti-interference free-space optical communication. The selective-response device suppresses stray illumination by more than three orders of magnitude, while the transmitter can be implemented using a conventional laser diode driven by a function generator. The extension of this strategy to PbS and PbI2-based systems supports its material generality, indicating a general route to photodetectors with application-defined response characteristics.

Для цитирования: Yang Siping, Zhang Jiaqing, Sun Haoxuan, Zhou Yicheng, Zhang Chi, Yang Tianrun, Huang Yongrong, Min Liangliang, Cao Fengren, Li Liang. Perovskite Photodetectors With Customizable Frequency Response.. Advanced materials (Deerfield Beach, Fla.). 2026. DOI: 10.1002/adma.75093.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.