MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jormas.2018.09.002

Медицинская библиотека · Journal of stomatology, oral and maxillofacial surgery · 2018

Development and validation of an optimized finite element model of the human orbit.

Foletti J M, Martinez V, Graillon N, Godio-Raboutet Y, Thollon L, Guyot L

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The authors' main purpose was to develop a detailed finite element model (FEM) of the human orbit and to validate it by analyzing its behavior under the stress of blunt traumas.

MATERIALS AND

METHODS

A pre-existing 3D FEM of a human head was modified and used in this study. Modifications took into account preliminary research carried out on PubMed database. Data from a CT scan of the head were computed with Mimics® software to re-create the skull geometry. The mesh production, the model's properties and the simulations of blunt orbital traumas were conducted on Hyperworks® software.

RESULTS

The resulting 3D FEM was composed of 640 000 elements and was used to perform blunt trauma simulations on an intact orbit. A total of 27 tests were simulated. Fifteen tests were realized with a metallic cylinder impactor; 12 tests simulated a hit by a closed fist. In all the tests conducted (27/27), the orbital floor was fractured. Fracture patterns were similar to those found in real clinical situations according to the buckling and hydraulic theories of orbital floor fractures.

DISCUSSION: The similitude between the fracture patterns produced on the model and those observed in vivo allows for a validation of the model. This model constitutes, at the authors knowledge, the most sophisticated one ever developed.

Для цитирования: Foletti J M, Martinez V, Graillon N, Godio-Raboutet Y, Thollon L, Guyot L. Development and validation of an optimized finite element model of the human orbit.. Journal of stomatology, oral and maxillofacial surgery. 2018. DOI: 10.1016/j.jormas.2018.09.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.