Fully Automated Placental Volume Quantification From 3D Ultrasound for Prediction of Small-for-Gestational-Age Infants.

Schwartz Nadav, Oguz Ipek, Wang Jiancong, Pouch Alison, Yushkevich Natalie, Parameshwaran Shobhana, Gee James, Yushkevich Paul, Oguz Baris

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Early placental volume (PV) has been associated with small-for-gestational-age infants born under the 10th/5th centiles (SGA10/SGA5). Manual or semiautomated PV quantification from 3D ultrasound (3DUS) is time intensive, limiting its incorporation into clinical care. We devised a novel convolutional neural network (CNN) pipeline for fully automated placenta segmentation from 3DUS images, exploring the association between the calculated PV and SGA.

METHODS

Volumes of 3DUS obtained from singleton pregnancies at 11-14 weeks' gestation were automatically segmented by our CNN pipeline trained and tested on 99/25 images, combining two 2D and one 3D models with downsampling/upsampling architecture. The PVs derived from the automated segmentations (PVCNN ) were used to train multivariable logistic-regression classifiers for SGA10/SGA5. The test performance for predicting SGA was compared to PVs obtained via the semiautomated VOCAL (GE-Healthcare) method (PVVOCAL ).

RESULTS

We included 442 subjects with 37 (8.4%) and 18 (4.1%) SGA10/SGA5 infants, respectively. Our segmentation pipeline achieved a mean Dice score of 0.88 on an independent test-set. Adjusted models including PVCNN or PVVOCAL were similarly predictive of SGA10 (area under curve [AUC]: PVCNN  = 0.780, PVVOCAL  = 0.768). The addition of PVCNN to a clinical model without any PV included (AUC = 0.725) yielded statistically significant improvement in AUC (P < .05); whereas PVVOCAL did not (P = .105). Moreover, when predicting SGA5, including the PVCNN (0.897) brought statistically significant improvement over both the clinical model (0.839, P = .015) and the PVVOCAL model (0.870, P = .039).

CONCLUSIONS

First trimester PV measurements derived from our CNN segmentation pipeline are significantly associated with future SGA. This fully automated tool enables the incorporation of including placental volumetric biometry into the bedside clinical evaluation as part of a multivariable prediction model for risk stratification and patient counseling.

Для цитирования: Schwartz Nadav, Oguz Ipek, Wang Jiancong, Pouch Alison, Yushkevich Natalie, Parameshwaran Shobhana, Gee James, Yushkevich Paul, Oguz Baris. Fully Automated Placental Volume Quantification From 3D Ultrasound for Prediction of Small-for-Gestational-Age Infants.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2021. DOI: 10.1002/jum.15835.