DOI 10.1007/s40618-021-01540-5
Volumetric evaluation of CT images of adrenal glands in primary aldosteronism.
Аннотация
OBJECTIVES
To investigate whether adrenal volumetry provides better agreement with adrenal vein sampling (AVS) than conventional CT for subtyping PA. Furthermore, we evaluated whether the size of this contralateral adrenal was a prognostic factor for clinical outcome after unilateral adrenalectomy.
METHODS
We retrospectively analyzed volumes of both adrenal glands of the 180 CT-scans (88/180 with unilateral and 92/180 with bilateral disease) of the patients with PA included in the SPARTACUS trial of which 85 also had undergone an AVS. In addition, we examined CT-scans of 20 healthy individuals to compare adrenal volumes with published normal values.
RESULTS
Adrenal volume was higher for the left than the right adrenal (mean and SD: 6.49 ± 2.77 ml versus 5.25 ± 1.87 ml for the right adrenal; p < 0.001). Concordance between volumetry and AVS in subtyping was 58.8%, versus 51.8% between conventional CT results and AVS (p = NS). The volumes of the contralateral adrenals in the patients with unilateral disease (right 4.78 ± 1.37 ml; left 6.00 ± 2.73 ml) were higher than those of healthy controls reported in the literature (right 3.62 ± 1.23 ml p < 0.001; left 4.84 ± 1.67 ml p = 0.02). In a multivariable analysis the contralateral volume was not associated with biochemical or clinical success, nor with the defined daily doses of antihypertensive agents at 1 year follow-up.
CONCLUSIONS
Volumetry of the adrenal glands is not superior to current assessment of adrenal size by CT for subtyping patients with PA. Furthermore, in patients with unilateral disease the size of the contralateral adrenal is enlarged but its size is not associated with outcome.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.