BACKGROUND

Cranial vault defects can pose a significant problem for neurosurgeons where autologous bone is no longer available for cranioplasty. Numerous materials exist to create implants which include polymethyl methacrylate (PMMA) and titanium. A technique using 3-dimensional CT scan reconstruction of a cranial defect and creating a silicon mould which can be autoclaved in theatre to create a PMMA implant was developed.

OBJECTIVE

The aim of this study is to evaluate the efficacy, cosmetic result, safety and cost-effectiveness of this procedure and compare this to existing techniques.

METHOD: An ambispective study was performed in patients requiring cranioplasty with a custom made implant. Patients were assessed for risk factors and cosmetic outcome, surgical technique was described and complications and cost compared to existing literature between 2010 and 2016.

RESULTS

Thirty retrospective and 30 consecutive prospective patients were recruited into the study. Overall sepsis rate was 8.3%. All septic cases had superficial sepsis of which 2 grafts were removed due to cerebrospinal fluid leakage resulting in wound breakdown. A 100% accurate implant to defect ratio was achieved leading to a high satisfaction rate. Average cost was 5 times cheaper than the closest market related product.

CONCLUSION

Patient specific moulds using PMMA to create custom implants are safe, have excellent cosmetic results and are a very cost-effective option to manage cranial defects. Accurate planning strategies for large craniotomies, where bone will potentially be discarded, add to surgical effectiveness and cost-saving to the patient.

Для цитирования: Vlok A J, Naidoo S, Kamat A S, Lamprecht D. Evaluation of locally manufactured patient-specific custom made implants for cranial defects using a silicone mould.. South African journal of surgery. Suid-Afrikaanse tydskrif vir chirurgie. 2018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.