Usefulness of Red Blood Cell Distribution Width in the Assessment of Hemodynamics After Tetralogy of Fallot Repair.

Kojima Takuro, Imamura Tomohiko, Osada Yousuke, Muraji Shouta, Nakano Marie, Oyanagi Takayuki, Yoshiba Shigeki, Kobayashi Toshiki, Sumitomo Naokata

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There are no reports on the effect of red blood cell distribution width (RDW) in surgical repair of tetralogy of Fallot (ToF).

METHODS AND

RESULTS

A total of 50 patients who underwent cardiac catheterization after surgical repair of ToF were retrospectively assessed. RDW was positively correlated with the ratio of right ventricular pressure to left ventricular pressure (RVP/LVP; P<0.0001, r2=0.57). Patients with elevated RDW had a higher RVP/LVP than those with a normal RDW (P<0.0001). Also, elevated RDW was related to elevated central venous pressure (P<0.0001), decreased mixed venous oxygen saturation (P<0.0001), greater pulmonary stenosis (P=0.003) and severe pulmonary regurgitation on echocardiography (P<0.0001), a higher rate of residual ventricular septal defect leak (P=0.004) and higher reoperation rate (P=0.009). Of the 7 patients who underwent reoperation, 6 had decrease in RDW after reoperation (P=0.012). On multivariable regression analysis, RDW was the strongest indicator of higher RVP/LVP.

CONCLUSIONS

For the first time, RDW has been shown to be a strong indicator for assessing the hemodynamics and risk of later reoperation after surgical repair of ToF.

Для цитирования: Kojima Takuro, Imamura Tomohiko, Osada Yousuke, Muraji Shouta, Nakano Marie, Oyanagi Takayuki, Yoshiba Shigeki, Kobayashi Toshiki, Sumitomo Naokata. Usefulness of Red Blood Cell Distribution Width in the Assessment of Hemodynamics After Tetralogy of Fallot Repair.. Circulation journal : official journal of the Japanese Circulation Society. 2019. DOI: 10.1253/circj.cj-18-1016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.