PURPOSE: To examine cone density in relation to gestational and morphological parameters in the Copenhagen Child Cohort (CCC2000).

METHODS

The macula was imaged using adaptive optics in 1,296 adolescents aged 16-17 years. Axial length and distance visual acuity were determined. Absolute and angular cone photoreceptor density were analysed for an 80 × 80-pixel area, 2 degrees temporal to the fovea. Association with axial length was analysed with linear regression. Correlation with visual acuity was described with a Pearson correlation coefficient. Associations of cone density with gestational parameters, maternal smoking, sex and age were analysed using multiple regression adjusted for axial length.

RESULTS

Mean absolute cone density was 30,007 cones/mm2 (SD ± 3,802) and mean angular cone density was 2,383 cones/deg2 (SD ± 231). Peri- and postnatal parameters, sex and age had no statistically significant effect on cone density (p > 0.05). Absolute cone density decreased with longer axial length (-2,855 cones/mm2 per mm or -9.7% per mm, p < 0.0001). For angular density, which included a correction for the geometrical enlargement of the eye with axial length, a decrease with axial length was detectable, but it was small (-20 cones/deg2 per mm or -0.84% per mm, p = 0.009).

CONCLUSIONS

The decrease in cone density per unit solid angle with increasing axial length was small, less than 1 percent per mm, indicating that expansion of the posterior pole during the development of refraction takes place without a clinically significant loss of cones. Perinatal parameters, within the spectrum presented by the study population, had no detectable effect on cone density.

Для цитирования: Eckmann-Hansen Christina, Hansen Mathias Hvidtfelt, Laigaard Poul Pedersen, Sander Birgit Agnes, Munch Inger Christine, Olsen Else Marie, Skovgaard Anne Mette, Larsen Michael. Cone photoreceptor density in the Copenhagen Child Cohort at age 16-17 years.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2021. DOI: 10.1111/opo.12889.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.