Human immunology · 2017
Relationship between Mean Fluorescence Intensity and C1q/C3d-fixing capacities of anti-HLA antibodies.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Claisse Guillaume, Absi Lena, Cognasse Fabrice, Alamartine Eric, Mariat Christophe, Maillard Nicolas
Аннотация
BACKGROUND: Complement-binding assays are proposed to better stratify the risk of antibody-mediated rejection associated-graft failure. Despite promising clinical results, some have suggested that the MFI of anti-HLA antibodies may influence these tests.
METHODS: We investigated the impact of Abs MFI reduction, induced by plasmapheresis, on C1q- and C3d-binding assays. Sera provided from 7 sensitized kidney transplant patients were analyzed.
RESULTS: Four hundreds and thirty-three SABs were analyzed. Before plasmapheresis, when compared to C1q- SABs, C1q+ SABs had a higher median MFI [17397 (IQR: 14851-18794) vs. 2745 (IQR: 1125-6476), p<0.01]. SABs that remained C1q+ after plasmapheresis had a higher median MFI. Regarding the C3d assay, results were strictly comparable. MFI value was a powerful predictor of both C1q and C3d positivity [AUC 0.97 (CI95% 0.95-0.99) and 0.96, (CI95% 0.93-0.98), respectively].
CONCLUSION: Our data suggest that both C1q- and C3d-binding assays are intimately linked to the MFI of anti-HLA Abs.
METHODS: We investigated the impact of Abs MFI reduction, induced by plasmapheresis, on C1q- and C3d-binding assays. Sera provided from 7 sensitized kidney transplant patients were analyzed.
RESULTS: Four hundreds and thirty-three SABs were analyzed. Before plasmapheresis, when compared to C1q- SABs, C1q+ SABs had a higher median MFI [17397 (IQR: 14851-18794) vs. 2745 (IQR: 1125-6476), p<0.01]. SABs that remained C1q+ after plasmapheresis had a higher median MFI. Regarding the C3d assay, results were strictly comparable. MFI value was a powerful predictor of both C1q and C3d positivity [AUC 0.97 (CI95% 0.95-0.99) and 0.96, (CI95% 0.93-0.98), respectively].
CONCLUSION: Our data suggest that both C1q- and C3d-binding assays are intimately linked to the MFI of anti-HLA Abs.