MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.juro.2016.03.177

Медицинская библиотека · The Journal of urology · 2016

Preoperative Urodynamic Parameters (Valsalva Leak Point Pressure and Maximum Urethral Closure Pressure), Urinary Collagen and Plasma Vitamin D Levels as Predictors of Mid Urethral Sling Surgery Outcome.

Chai Toby C, Moalli Pamela A, Richter Holly E, Lake AeuMuro G, Kim Hae-Young, Nager Charles W, Sirls Larry T, Brubaker Linda, Kusek John W

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To determine the best predictor of the mid urethral sling outcome we calculated the AUC of ROC curves of preoperative parameters, including Valsalva leak point pressure, maximum urethral closure pressure, urinary NTx (N-telopeptide of crosslinked type I collagen) and plasma vitamin D values (D2, D3 and D2 plus D3).

MATERIALS AND

METHODS

This was an ancillary study of TOMUS (Trial of Mid-urethral Slings) and the ValUE (Value of Urodynamics Evaluation) trial in which subjects underwent mid urethral sling surgery for stress urinary incontinence. Valsalva leak point pressure and maximum urethral closure pressure were measured in 427 subjects, whereas NTx, vitamin D2, vitamin D3 and vitamin D2 plus D3 levels were obtained from 150, 116, 115 and 116 subjects respectively. Outcome success was defined using identical outcome (subjective and objective) variables for all subjects. ROC curves with corresponding AUC values were compared.

RESULTS

TOMUS and ValUE subjects were significantly different in age, body mass index, UDI (Urogenital Distress Inventory) scores. TOMUS subjects had a lower surgical success rate compared to ValUE subjects (66.3% vs 76.0%, p = 0.03). The AUC values of Valsalva leak point pressure, maximum urethral closure pressure, NTx, and vitamins D2, D3 and D2 plus D3 were 0.542, 0.561, 0.702, 0.627, 0.645 and 0.640, respectively. The AUC of NTx was significantly higher than the AUCs of Valsalva leak point pressure and maximum urethral closure pressure (p = 0.02 and 0.03, respectively).

CONCLUSIONS

Urinary NTx was the best predictor of the mid urethral sling outcome. This test is not only noninvasive, it is also modifiable. Finding ideal modifiable risk factors prior to mid urethral sling surgery should be subject to future investigations.

Для цитирования: Chai Toby C, Moalli Pamela A, Richter Holly E, Lake AeuMuro G, Kim Hae-Young, Nager Charles W, Sirls Larry T, Brubaker Linda, Kusek John W. Preoperative Urodynamic Parameters (Valsalva Leak Point Pressure and Maximum Urethral Closure Pressure), Urinary Collagen and Plasma Vitamin D Levels as Predictors of Mid Urethral Sling Surgery Outcome.. The Journal of urology. 2016. DOI: 10.1016/j.juro.2016.03.177.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.