MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003086-199811000-00031

Медицинская библиотека · Clinical orthopaedics and related research · 1998

Small wire external fixation of high energy tibial plateau fractures.

Mikulak S A, Gold S M, Zinar D M

СтатьяПеревод в очереди

Аннотация

Open plate osteosynthesis for high energy tibial plateau fractures with dissociation between the metaphysis and diaphysis has been plagued with frequent soft tissue complications. The Harbor-University of California at Los Angeles Medical Center's experience with small wire external fixation supplemented by limited internal fixation is examined. This alternative method of adequate stable fixation offers the advantage of minimal soft tissue compromise. Twenty-four patients with Schatzker Type VI tibial fractures were treated with small wire external fixation. Supplementary limited internal fixation was used with percutaneous screws in 10 patients and with open reduction in one patient. Sixteen patients had isolated fractures, and eight others suffered multiple injuries. Minimum followup was 12 months. All fractures healed. Complications included one septic knee, two infections at screw sites, and one 10 degrees knee flexion contracture. One knee had Grade 3 radiographic arthrosis, five had Grade 2, 10 had Grade 1, and eight showed no arthrosis. The outcomes (Knee Society clinical rating system) of this study compare favorably with outcomes described in reports published previously for this type of fracture, despite inclusion of eight multiply injured patients. This technique preserves the goals of early range of motion and stable fixation for these devastating injuries, while decreasing the observed major wound complications and nonunion rates. However, longer followup may reveal higher arthrosis rates, specifically in those fractures that were not anatomically reduced.

Для цитирования: Mikulak S A, Gold S M, Zinar D M. Small wire external fixation of high energy tibial plateau fractures.. Clinical orthopaedics and related research. 1998. DOI: 10.1097/00003086-199811000-00031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.