[Valve replacement in congenital aortic stenosis].

Dominik J, Brzek V, Simek J, Procházka E

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

BACKGROUND

Hemodynamically significant congenital aortic stenosis is usually surgically solved by valvotomy, infrequently aortic valve replacement is necessary. The aim of this retrospective study (period 1979-1995) is to find reasons for valve replacement, frequency of these procedures and early and long term results after aortic valve replacement for congenital aortic stenosis.

METHODS AND

RESULTS

Congenital aortic stenosis was solved by aortic valvotomy in 82 patients and by aortic valve replacement in 18 patients. Aortic valve replacement was performed 6x for congenital valvar aortic stenosis with mean aortic gradient 53.7 +/- 13.9 mm Hg and aortic valve area 0.42 +/- 0.04 cm2/m2 and 4x for valvar and subvalvar stenosis with mean aortic gradient 87.0 +/- 31.3 mm Hg, valve area 0.45 +/- 0.03 cm2/m2 and associated regurgitation 44.7 +/- 25.6%. In the remaining 8 patients aortic valve replacement was performed as reoperation after aortic valvotomy (after 20 +/- 8.4 years). In this group mean aortic gradient was only 32.2 +/- 13.8 mm Hg but regurgitation was 54.0 +/- 15.8%. Infective endocarditis occurred in 8 patients (44.5%) preoperatively. There were two hospital deaths (sudden death and multiorgan failure) and one death 3 years after operation (prosthetic endocarditis). Remaining 15 patients are in very good condition (NYHA I.-II.) 1-13 years after aortic valve replacement.

CONCLUSIONS

Severely calcified aortic valve, endocarditis and associated incompetence are indications for valve replacement in patients with congenital aortic valve disease. Prevention of infective endocarditis is necessary pre and postoperatively, too. Long-term results after valve replacement for aortic valve stenosis are very good.

Для цитирования: Dominik J, Brzek V, Simek J, Procházka E. [Valve replacement in congenital aortic stenosis].. Casopis lekaru ceskych. 1997.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.