Successful magnetic resonance-guided focused ultrasound treatment of tremor in patients with a skull density ratio of 0.4 or less.

Vetkas Artur, Boutet Alexandre, Sarica Can, Germann Jurgen, Gwun Dave, Yamamoto Kazuaki, Jung Hyun Ho, Alkhotani Afnan, Samuel Nardin, Lang Stefan, Conner Christopher R, Elias Gavin J B, Cheyuo Cletus, Chow Clement, Santyr Brendan, Iorio-Morin Christian, Yang Andrew Z, Candeias da Silva Carolina, Fasano Alfonso, Kalia Suneil K, Lozano Andres M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The use of magnetic resonance-guided focused ultrasound (MRgFUS) for the treatment of tremor-related disorders and other novel indications has been limited by guidelines advocating treatment of patients with a skull density ratio (SDR) above 0.45 ± 0.05 despite reports of successful outcomes in patients with a low SDR (LSDR). The authors' goal was to retrospectively analyze the sonication strategies, adverse effects, and clinical and imaging outcomes in patients with SDR ≤ 0.4 treated for tremor using MRgFUS.

METHODS

Clinical outcomes and adverse effects were assessed at 3 and 12 months after MRgFUS. Outcomes and lesion location, volume, and shape characteristics (elongation and eccentricity) were compared between the SDR groups.

RESULTS

A total of 102 consecutive patients were included in the analysis, of whom 39 had SDRs ≤ 0.4. No patient was excluded from treatment because of an LSDR, with the lowest being 0.22. Lesioning temperatures (> 52°C) and therapeutic ablations were achieved in all patients. There were no significant differences in clinical outcome, adverse effects, lesion location, and volume between the high SDR group and the LSDR group. SDR was significantly associated with total energy (rho = -0.459, p < 0.001), heating efficiency (rho = 0.605, p < 0.001), and peak temperature (rho = 0.222, p = 0.025).

CONCLUSIONS

The authors' results show that treatment of tremor in patients with an LSDR using MRgFUS is technically possible, leading to a safe and lasting therapeutic effect. Limiting the number of sonications and adjusting the energy and duration to achieve the required temperature early during the treatment are suitable strategies in LSDR patients.

Для цитирования: Vetkas Artur, Boutet Alexandre, Sarica Can, Germann Jurgen, Gwun Dave, Yamamoto Kazuaki, Jung Hyun Ho, Alkhotani Afnan, Samuel Nardin, Lang Stefan, Conner Christopher R, Elias Gavin J B, Cheyuo Cletus, Chow Clement, Santyr Brendan, Iorio-Morin Christian, Yang Andrew Z, Candeias da Silva Carolina, Fasano Alfonso, Kalia Suneil K, Lozano Andres M. Successful magnetic resonance-guided focused ultrasound treatment of tremor in patients with a skull density ratio of 0.4 or less.. Journal of neurosurgery. 2023. DOI: 10.3171/2023.6.jns23171.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.