DOI 10.1007/s11325-018-1652-4

Медицинская библиотека · Sleep & breathing = Schlaf & Atmung · 2018

Cycle length identifies obstructive sleep apnea and central sleep apnea in heart failure with reduced ejection fraction.

Bitter Thomas, Özdemir Burak, Fox Henrik, Horstkotte Dieter, Oldenburg Olaf

СтатьяПеревод в очереди

Аннотация

AIM: To clarify whether unmasking of central sleep apnea during continuous positive airway pressure (CPAP) initiation can be identified from initial diagnostic polysomnography (PSG) in patients with heart failure with reduced ejection fraction (HFREF) and obstructive sleep apnea (OSA) MATERIALS AND

METHODS

Forty-three consecutive patients with obstructive sleep apnea and central sleep apnea (OSA/CSA) in HFREF were matched with 43 HFREF patients with OSA and successful CPAP initiation. Obstructive apneas during diagnostic PSG were then analyzed for cycle length (CL), ventilation length (VL), apnea length (AL), time to peak ventilation (TTPV), and circulatory delay (CD). We calculated duty ratio (DR) as the ratio of VL/CL and mathematic loop gain (LG).

RESULTS

While AL was similar, CL, VL, TTPV, CD, and DR was significantly longer in patients with OSA/CSA compared to those with OSA, and LG was significantly higher. Receiver operator curves identified optimal cutoff values of 50.2 s for CL (area under the curve (AUC) 0.85, 29.2 s for VL (AUC 0.92), 11.5 s for TTPV (AUC 0.82), 26.4 s for CD (AUC 0.79), and 3.96 (AUC 0.78)) respectively for LG to identify OSA/CSA.

CONCLUSION

OSA/CSA in HFREF can be identified by longer CL, VL, TTPV, and CD from obstructive events in initial diagnostic PSG. The underlying mechanisms seem to be the presence of an increased LG.

Для цитирования: Bitter Thomas, Özdemir Burak, Fox Henrik, Horstkotte Dieter, Oldenburg Olaf. Cycle length identifies obstructive sleep apnea and central sleep apnea in heart failure with reduced ejection fraction.. Sleep & breathing = Schlaf & Atmung. 2018. DOI: 10.1007/s11325-018-1652-4.