MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpedsurg.2019.08.029

Медицинская библиотека · Journal of pediatric surgery · 2019

The outcome of real-time evaluation of biliary flow using near-infrared fluorescence cholangiography with Indocyanine green in biliary atresia surgery.

Yanagi Yusuke, Yoshimaru Koichiro, Matsuura Toshiharu, Shibui Yuichi, Kohashi Kenichi, Takahashi Yoshiaki, Obata Satoshi, Sozaki Ryota, Izaki Tomoko, Taguchi Tomoaki

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Indocyanine green (ICG) fluorescence imaging is a promising tool for intraoperative decision-making. The aim of this study was to evaluate the utility of near-infrared fluorescence cholangiography (NIR-FCG) with ICG in primary surgery for biliary atresia (BA).

METHODS

We performed NIR-FCG with ICG in 10 BA patients and observed the fluorescence of their hilar micro-bile ducts and hilar exudate in order to assess the appropriate level at which to dissect the hilar fibrous corn. We compared the jaundice outcome of 10 patients using NIR-FCG (Group A) to that of 35 historical patients in whom NIR-FCG had not been used (Group B).

RESULTS

The mean age of patients was 74.8 days. The classification of BA was type I in two cases and type-III in eight cases. NIR-FCG visualized the hilar micro-bile ducts, and the incidence of positive fluorescence was 80%. The ratio of postoperative normalization of hyperbilirubinemia in Group A was significantly higher than that in Group B (1.0 vs. 0.65, p < 0.05).

CONCLUSION

NIR-FCG provided important objectifiable information about the biliary structures in surgery of BA. Although the number of cases was small, our results suggest that NIR-FCG may be useful for improving the outcome of primary surgery for BA.

TYPE OF STUDY: Study of Diagnostic Test.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Yanagi Yusuke, Yoshimaru Koichiro, Matsuura Toshiharu, Shibui Yuichi, Kohashi Kenichi, Takahashi Yoshiaki, Obata Satoshi, Sozaki Ryota, Izaki Tomoko, Taguchi Tomoaki. The outcome of real-time evaluation of biliary flow using near-infrared fluorescence cholangiography with Indocyanine green in biliary atresia surgery.. Journal of pediatric surgery. 2019. DOI: 10.1016/j.jpedsurg.2019.08.029.